Back to search

University of Birmingham

A study to investigate discomfort associated with fixed orthodontic appliances

Abstract

dc:description.abstract

Aims The aims of this study were: 1) To determine levels of pain experienced by patients following the placement of fixed orthodontic appliances 2) To determine if an acrylic bite wafer is effective in reducing the pain experienced after fixed appliance placement 3) To determine if an acrylic bite wafer is any more effective in reducing pain experience than merely providing advice Null Hypotheses • Chewing on an acrylic bite wafer following placement of fixed orthodontic appliances, does not reduce the pain and discomfort experienced • Chewing on an acrylic bite wafer does not provide a significant reduction in pain experience as compared to providing advice and instructions Method 60 subjects aged 12-16 years who were attending to begin fixed appliance treatment were randomly assigned to one of two groups. Participants were asked to rate their anxiety level on a questionnaire. Then they were asked to perform 4 simple biting exercises and mark their level of discomfort on a visual analogue scale. Those in the first group were given a bite wafer to chew for 15 minutes immediately after having their fixed orthodontic appliances placed. The second group had fixed appliances placed in the normal manner and received standard advice. Both groups were then asked to complete a questionnaire rating discomfort at intervals over the next 7 days. ANOVA was used to compare group scores after various times. Pain scores between the two groups were compared using Two-sample t-tests where appropriate. Results The pain experienced after appliance placement (no wafer group) increased and peaked at 24 hours (mean VA scores 0.70, 0.75, 0.65 and 0.67 for the 4 exercises respectively). Thereafter the pain reduced and reached baseline levels at 7 days (mean VA scores 0.08, 0.19, 0.09 and 0.10). Chewing on the acrylic bite wafer immediately after appliance placement resulted in a slightly lower total pain experience over the first 7 days than if no wafer was used, although the difference between the groups was not significant (t = -0.34/p = 0.74, t = -0.66/p = 0.52, t =-0.31/p = 0.76, t = -0.82/p = 0.43). Conclusions Chewing on an acrylic bite wafer slightly reduced pain experience after appliance placement and was more effective than providing standard advice and instructions, although the pain reductions were not statistically significant.

Degree

thesis:*
Name dc:type.qualificationname
m_ph
Level dc:type.qualificationlevel
m_ph
Grantor dc:publisher.institution
University of Birmingham
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bhogal, Preetpal Singh

Subjects

dc:subject × 1

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
University of Birmingham
Base URL
etheses.bham.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Bhogal, Preetpal Singh. A study to investigate discomfort associated with fixed orthodontic appliances. m_ph thesis, University of Birmingham, 2009.