Back to search

University of Birmingham

Secure user-driven pairing with implantable medical devices

Abstract

dc:description.abstract

Implantable Medical Devices (IMDs), such as pacemakers and insulin pumps, are widely deployed today and often use wireless communication with external devices. Establishing a secure communication channel with an IMD can be life-critical. However, this is challenging in practice due to the special properties and needs of these devices. To address this issue, researchers and medical device companies have developed various types of pairing techniques for IMDs, aiming to bootstrap a cryptographic key between an IMD and an external device to secure the subsequent wireless communications. In this thesis, we investigate these techniques and analyze their security, usability, and deployability (i.e., whether the methods can be deployed in real-world devices) properties. Specifically, we highlight a worrying drawback in existing work: The pairing process with an IMD is always designed to be imperceptible to the patient. Assume a patient with a pacemaker is in a crowded public space (like a bus or a mall), a malicious adversary could potentially approach the patient and silently pair with their pacemaker without the patient noticing, which can lead to life-threatening consequences, e.g., changing their therapy. To mitigate this concern, we introduce several novel user-driven IMD pairing techniques, where pairing can be completed only after the user conducts specific physical interactions with the patient's body, e.g., tapping on their body for a few times. Our approach makes the pairing process highly perceptible, and thus allows the patient to detect and stop the pairing at any time. We implement prototypes for our proposed techniques, and thoroughly evaluate them with human participants. Furthermore, we comprehensively validate whether our protocol can be potentially deployed in today's modern IMD products. The results demonstrate promising potential for our proposed pairing techniques. Our findings point out a new direction for future user-friendly design of security solutions for IMDs, and can provide value to both academia and medical device industry.

Degree

thesis:*
Name dc:type.qualificationname
d_ph
Level dc:type.qualificationlevel
d_ph
Grantor dc:publisher.institution
University of Birmingham
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Mo
ORCID person:identifier.orcid

Subjects

dc:subject × 2

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
University of Birmingham
Base URL
etheses.bham.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Zhang, Mo. Secure user-driven pairing with implantable medical devices. d_ph thesis, University of Birmingham, 2025.