Back to search

University of Birmingham

Establishing continuous planar laser-induced fluorescence to evaluate static mixers in conjunction with particle tracking computational fluid dynamics

Abstract

dc:description.abstract

A test facility was developed to enable continuous Planar Laser-Induced Fluorescence (PLIF) for the evaluation of static mixers. By integrating an activated carbon-based filtration system, the Rhodamine 6G tracer compound was adsorbed from spent glycerol test fluid, allowing it to be recycled back into the loop. Drawing inspiration from industrial techniques, the test rig incorporated comprehensive digital data acquisition and control systems, enabling remote management of temperature (and thus viscosity) and mass flow. All operational parameters were measured automatically and recorded to a database, facilitating autonomous operation through pre-programmed state machines and control via PID algorithms. To validate the accuracy and repeatability of flow properties, static mixer pressure drop tests were conducted, confirming the reliability of the on-line pipe rheometer across different glycerol mass fractions. Comprehensive PLIF imagery was captured at the outlets of various static mixers following the injection of Rhodamine 6G dye at their inlets. Included static mixers are the SMX™, SMX™ plus, Chemineer Kenics, and a new static mixer design from CALGAVIN. The high-resolution images were quantitatively analysed using coefficient of variance (CoV) and a newly proposed CG Number to assess the consistency and effectiveness of mixing under different flow conditions. Concurrently, a novel flux-based particle tracking computational fluid dynamics (CFD) methodology was developed, translating Lagrangian simulations back into Eulerian space. This approach enables CFD simulations to mirror experimental PLIF testing by producing images with a non-binary dynamic range while avoiding the numerical diffusion issues associated with passive scalar techniques. By combining this CFD method with experimental PLIF results, rapid prototyping of static mixer designs is facilitated, allowing computational testing of variations prior to fabrication and experimental validation of the most promising designs.

Degree

thesis:*
Name dc:type.qualificationname
d_en
Level dc:type.qualificationlevel
d_en
Grantor dc:publisher.institution
University of Birmingham
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Robinson, Thomas
ORCID person:identifier.orcid

Subjects

dc:subject × 1

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
University of Birmingham
Base URL
etheses.bham.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Robinson, Thomas. Establishing continuous planar laser-induced fluorescence to evaluate static mixers in conjunction with particle tracking computational fluid dynamics. d_en thesis, University of Birmingham, 2025.