Back to search

University of Birmingham

Unsupervised deep learning for removing structured noise in microscopy and flow cytometry

Abstract

dc:description.abstract

Microscopy and flow cytometry are pillars of life science research. They use agents such as light or electrons to analyse the structure and composition of biological samples at micrometre and nanometre scales. However, the samples can be damaged by this very process, resulting in observations that do not capture them in their most natural state. Illumination intensity must therefore be minimised, but this reduces the ratio of signal to noise. When signal intensity is limited by practical constraints, and noise cannot be mitigated at the time of observation, denoisers must be employed to estimate the signal underlying a noisy observation post hoc. Currently, the most accurate estimates are made by deep learning-based denoisers. Their strength comes from utilising the information contained in training data, but this is also one of their greatest limitations. To reliably remove all forms of noise, existing deep learning-based denoisers require paired training data, typically consisting of noisy observations and corresponding clean signals. In the life sciences, paired data and clean signals may be unobtainable. Techniques exist to train denoisers with unpaired noisy observations, i.e., the very data that is to be denoised, but these face another challenge: structured noise. Structured noise is prevalent in both microscopy and flow cytometry, and it is defined as noise that is correlated over pixels or time points. Currently, no deep learning-based denoiser can reliably remove it without either paired training data or by making sacrifices in the quality of the output. In this thesis, we develop unsupervised deep learning-based denoisers for structured noise as it commonly occurs in microscopy and flow cytometry. These methods are trained without paired observations or clean signals, and have quality approaching and sometimes exceeding that of denoisers trained with paired data. We also identify another limitation of unsupervised deep learning-based denoisers – their slow inference time – and present a method to reduce their inference time by three orders of magnitude. We believe that the methods presented here will remove some of the biggest barriers to applying deep learning denoisers to life science data.

Degree

thesis:*
Name dc:type.qualificationname
d_ph
Level dc:type.qualificationlevel
d_ph
Grantor dc:publisher.institution
University of Birmingham
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Salmon, Benjamin Raymond
ORCID person:identifier.orcid

Subjects

dc:subject × 1

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
University of Birmingham
Base URL
etheses.bham.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Salmon, Benjamin Raymond. Unsupervised deep learning for removing structured noise in microscopy and flow cytometry. d_ph thesis, University of Birmingham, 2025.