Abstract

dc:description.abstract

A mechanical combined lung model is a type of model used in human breathing simulation. The biggest currency of the model is a high similarity with the human lungs. In order to work with the animal lungs for a longer time and so follow the principles of the 3Rs, a perfusion system is involved in the procedure. The perfusion system filled with a chosen perfusate solution is responsible to prolong the period in which the animal lungs are viable for experiments and storage in the ex-vivo environment. The development of the properly functioning perfusion system is based on the several components included in the process. Choosing the right solution for the perfusion of the inner environment of the lungs is one of the most important things that need to be taken into account. The roller pump is considered the drive motor of the system. Pressure and flow sensors are responsible for monitoring the process parameters that could describe the functionality and the ability to preserve the animal lungs in the ex-vivo environment. The validation of the developed system by using the fresh animal lungs is a part of the thesis as well as the checking procedure of the solution’s influence with the time of the storage. The perfusion system was successfully created and tested. The pressure and flow parameters gained during the measurement were compared while using the saline solution, the Ringer’s solution, and Histofix in the system. The compliance parameter of the lungs were been monitored during the perfusion as well as during the storage with the aim to determine the behaviour of the preserved lungs with the time and the impact of the chosen solution on it. Compliance initially decreased and then stabilized at a certain value throughout the storage period. For the perfusion with the saline and Ringer’s solution, it dropped by one-third. For Histofix preservation, the drop was by half of the initial compliance. The preservation time without the presence of the tissue necrosis was 120 hours using the Saline solution, 240 hours using the Ringer’s solution, and at least 268 hours using Histofix. The perfusion system could further be used in medical research and make a positive aspect in terms of less consumption of the animal organs for experimental purposes in various fields of the research. For future research, the improvement of the perfusion system and solution composition to ensure even longer preservation is welcomed.

Degree

thesis:*
Level thesis:degree_level
Inženýrský
Discipline thesis:degree_discipline
bez specializace
Grantor dc:publisher
Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mesíková, Klaudia
Advisor dc:contributor.advisor
  • Paštěka, Richard
Committee member dc:contributor.committeemember
  • Forjan, Mathias

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • Standardní licenční smlouva - přístup k plnému textu bez omezení
Language dc:language.iso
en, angličtina (English)

Identifiers

dc:identifier.*
Dc Identifier Citation
MESÍKOVÁ, K. Vývoj ex vivo plicního perfuzního systému pro animální modely [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2022.
Dc Identifier Other
137500

Chain of custody

source
Harvested from
Brno University of Technology
Base URL
dspace.vut.cz/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mesíková, Klaudia. Vývoj ex vivo plicního perfuzního systému pro animální modely. Inženýrský thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, http://hdl.handle.net/11012/208147