Back to search

Brock University

Wired versus Wireless Skin Temperature Measurement: Agreement Among a Thermocouple, an iButton®, and an eTemp Performance Sensor Across Warm, Thermoneutral, and Cool Conditions

Abstract

dc:description.abstract

Wireless contact sensors are increasingly used in place of wired ones for skin temperature measurement because they permit ambulatory recording. Whether the two device classes produce similar values across different ambient conditions typical of indoor environments is unclear. This thesis compared skin temperature measured simultaneously by a wired type-T thermocouple, a wireless iButton® data logger, and a wireless eTemp Performance real-time sensor during a multiphase thermal exposure protocol. Twenty-one healthy adults (11 males, 10 females; age 24 ± 8 years) stood in an environmental chamber for 100 minutes at 50% relative humidity while chamber temperature followed four phases: 23 °C for 10 minutes, 30 °C for 30 minutes, 18 °C for 30 minutes, and 23 °C for a final 30 minutes. Sensors were co-located beneath a single piece of Tegaderm® film at the chest, triceps, thigh, and calf, and mean weighted skin temperature (T̅sk) was calculated each minute using the Ramanathan four-site formula. Agreement was quantified by Bland-Altman analysis, proportional bias regression, Lin's concordance correlation coefficient (CCC), and Two One-Sided Tests against a ±0.5 °C margin. Pooled across the protocol, both wireless sensors read higher than the thermocouple and exceeded the thresholds of ≤±0.5 °C mean bias and ≤±1.0 °C 95% limits of agreement (iButton®: +0.960 °C, −0.833 to 2.753 °C; eTemp Performance: +0.973 °C, −0.524 to 2.470 °C). Disagreement was phase-dependent. Both wireless devices were statistically equivalent to the thermocouple within ±0.5 °C during the warm steady-state (30 °C), whereas mean bias exceeded 1.6 °C during the cool steady-state (18 °C), and the largest transient bias (+2.51 °C) occurred at the warm-to-cool transition. Bias scaled inversely with T̅sk. The two wireless sensors agreed closely with each other in every phase (pooled bias −0.029 °C; CCC 0.983). The wired thermocouple and the two wireless sensors are therefore not interchangeable for skin temperature measurement when a protocol includes cool ambient conditions or thermal transitions. The skin-to-environment thermal gradient appears to drive this divergence, which reflects error in both device classes rather than wireless error alone. The two wireless devices can reasonably be substituted for one another.

Degree

thesis:*
Name thesis:degree_name
M.Sc. Applied Health Sciences
Level thesis:degree_level
Master
Discipline thesis:degree_discipline
Faculty of Applied Health Sciences
Department dc:contributor.department
Applied Health Sciences Program
Grantor dc:publisher
Brock University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Corrêa Rodrigues, Eric Enrique
Advisor dc:contributor.advisor
  • Mündel, Toby

Subjects

dc:subject × 5

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10464/20709

Chain of custody

source
Harvested from
Brock University
Base URL
brocku.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Corrêa Rodrigues, Eric Enrique. Wired versus Wireless Skin Temperature Measurement: Agreement Among a Thermocouple, an iButton®, and an eTemp Performance Sensor Across Warm, Thermoneutral, and Cool Conditions. Master thesis, Brock University, 2026. https://hdl.handle.net/10464/20709