Back to search

Boston University

Instrument design and optimization of interferometric reflectance imaging sensors for in vitro diagnostics

Abstract

dc:description.abstract

In the field of drug discovery and disease diagnostics, protein microarrays have generated much enthusiasm for their high-throughput monitoring of biomarkers; however, this technology has yet to translate from research laboratories to commercialization. The hindrance is the considerable uncertainty and skepticism regarding data obtained. The disparity in results from different laboratories performing identical tests is attributed to a lack of assay quality control. Unlike DNA microarrays, protein microarrays have a higher level of bioreceptor immobilization variability and non-specific binding because of the more complex molecular structure and broader physiochemical properties. Traditional assay detection modalities, such as fluorescence microscopy and surface plasmon resonance, are unable to overcome both of these sources of variation. This dissertation describes the hardware and software design and biological validation of three complementary platforms that overcome bioreceptor variability and non-specific binding for diagnostics. In order to quantify the bioreceptor quality, a label-free, nondestructive, low cost, and high-throughput interferometric sensor has been developed as a quality control tool. The quality control tool was combined with a wide-field fluorescence imaging system to improve fluorescence experimental repeatability. Lastly, a novel high-throughput and label-free platform for quality control and specific protein microarray detection is described. This platform overcomes the additional complexities and time required with labeled assays by discriminating between specific and nonspecific detection by including sizing of individual binding events. Protein microarrays may one day emerge as routine clinical laboratory tests; however, it is important that the proper quality control procedures are in place to minimize erroneous results. These platforms provide reliable and repeatable protein microarray measurements for new advancements in disease diagnostics with the potential for drug discovery.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
Boston University
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Reddington, Alexander P.

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/11031

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Reddington, Alexander P.. Instrument design and optimization of interferometric reflectance imaging sensors for in vitro diagnostics. doctoral thesis, Boston University, 2014. https://hdl.handle.net/2144/11031