Back to search

Boston University

Seminal stain fluorescence using three alternate light source-barrier filter combinations on six different colors of cotton fabrics

Abstract

dc:description.abstract

Detecting and locating semen stains is crucial when creating a linkage between the offender and items of evidence. Currently, the two most common methods of semen stain detection used in crime scenes and items recovered from crime scenes are fluorescence and chemical examinations. An alternate light source (ALS), which causes semen to fluoresce under different wavelengths, is an established technique that utilizes converted light for the detection of latent stains. The other method relies on chemically identifying the presence of acid phosphatase activity in semen. Previous studies have concluded that semen optimally fluoresces at 450 nm wavelength with an orange barrier filter. In this paper, the fluorescence of seminal stains under different laboratory conditions is compared in order to investigate the significant factors that may affect semen detection. The variables investigated in this paper include six colors of plain cotton fabrics, three excitation spectra, three semen donors, five semen concentrations and six fabric textures. The intensity of the fluorescence was calculated using the image processing program ImageJ. ImageJ contains a color channel split function that allows photographs to split into 8-bit grayscale images containing the red, green and blue components of the original photographs. Each color channel was individually compared to each other and to the original RGB photographs to determine whether color channel splitting has an effect on the detectability of seminal stain fluorescence. This study suggests that the most significant factor that affects the detectability of a semen stain, aside from the concentration of the stain, is the color of the substrate. The texture of the substrate had no significant effect on the fluorescence and no significant variation in the semen stain fluorescence was observed from the three donors tested; however, future studies are necessary to confirm these findings. Forensic analysts should consider the background color when selecting the excitation light wavelength, and may need to utilize an alternate approach such as a chemical mapping examination, particularly for locating diluted semen stains on a dark background.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Forensic Sciences
Grantor
Boston University
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Su, Joey Young

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/16197

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Su, Joey Young. Seminal stain fluorescence using three alternate light source-barrier filter combinations on six different colors of cotton fabrics. masters thesis, Boston University, 2015. https://hdl.handle.net/2144/16197