Back to search

Boston University

The capability and accuracy of the CEREC CAD/CAM system to fabricate custom posts by direct scanning of simulated canal blocks in vitro

Abstract

dc:description.abstract

Dentists have been using CAD/CAM technology to fabricate custom posts and cores. However, most of these cases used impression material as a way to indirectly scan the canal. The aim of this study was to evaluate the capability of CEREC CAM/CAM machine to directly scan simulated canal blocks without an impression and which of the following factors affected the accuracy of fit; taper, length and tip diameter. Material and methods: 32 epoxy resin blocks with post space simulator were made from metal post templates to resemble post space preparations. Three factors were considered in-group variations; length of the post, taper and diameter of the post’s tip. Eight groups of four specimens each were milled from acrylic blocks using the CEREC CAD/CAM system and one extra group of one specimen each was for cast post fabrication. Group A (Length = 8mm, taper = 4o, tip diameter = 0.8mm), Group B (Length = 8mm, taper = 4o, tip diameter = 1 mm), Grope C (Length = 8mm, taper = 6o, tip diameter = 0.8mm), Group D (Length = 8mm, taper = 6o, tip diameter = 1 mm), Group E (Length = 10 mm, taper = 4o, tip diameter = 0.8mm), Group F (Length = 10 mm, taper = 4o, tip diameter = 1 mm), Grope G (Length = 10mm, taper = 6o, tip diameter = 0.8mm), Group H (Length = 10mm, taper = 6o, tip diameter = 1mm). Each block, with its cemented post was sectioned in a coronal-apical direction. An image was recorded for each slice. Cement thicknesses were measured in four areas. The results showed that group E and D have the smallest cement thickness with 84 and 89 microns respectively. Both groups shared a tip diameter of 1mm. This result is within the clinically acceptable limit of the cement layer around the posts and is comparable to the cast group in our study. Tip diameter and length significantly affected the cement thickness in an inverse relationship.

Degree

thesis:*
Name thesis:degree_name
Doctor of Science in Dentistry
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Endodontics
Grantor
Boston University
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bahabri, Rayan

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/18303

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Bahabri, Rayan. The capability and accuracy of the CEREC CAD/CAM system to fabricate custom posts by direct scanning of simulated canal blocks in vitro. doctoral thesis, Boston University, 2016. https://hdl.handle.net/2144/18303