Back to search

Boston University

Characterization of carbon electrode surfaces development of biosensors for forensic DNA applications

Abstract

dc:description.abstract

Quantitative polymerase chain reaction (qPCR) techniques are currently used to quantify samples containing deoxyribonucleic acid (DNA) in forensic analyses. This technology can provide valuable information to an analyst regarding the amount of DNA present but lacks the ability to determine the quality of the sample. Electrochemistry-based biosensors that utilize screen-printed electrodes may provide a method to determine the number of DNA molecules and the length of those molecules in a single assay. This work aimed to create a biosensor by electrostatically loading TPOX oligonucleotides onto a carbon screen-printed electrode for the purpose of quantifying genomic DNA. Electrochemical signal was obtained via the indicating molecule bis-benzimide H33258, which preferentially interacts with double-stranded DNA and would indicate a hybridization event. Cyclic voltammetry was chosen to measure the current signal; peaks obtained using this technique can be analyzed with the Randles-Sevčik equation, which relates current signal with concentration of the target species. A large amount of signal variation and background charging current was observed when H33258 was used as the redox probe. This led to a study of the surface characteristics of the carbon electrodes themselves (i.e. effective surface area) by utilizing the reversible and well-characterized redox couple hexaammine ruthenium. The effect of electrode activation at high anodic potentials was also studied. Though highly recommended in the literature, activation of the carbon surface caused effective surface area and charging current to increase. While a larger electro-active surface is often desirable, the high background current generated when activation is used within the protocol can mask the signal of interest. Due to the low signal-to-noise ratio and inability to reuse the carbon electrode, it was concluded that carbon screen printed electrodes are not optimal forensic DNA biosensors.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Forensic Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Bioforensics
Grantor dc:publisher
Boston University
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Churinsky, Candace Renee

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This work is being made available in OpenBU by permission of its author, and is available for research purposes only. All rights are reserved to the author.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/21139

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Churinsky, Candace Renee. Characterization of carbon electrode surfaces development of biosensors for forensic DNA applications. masters thesis, Boston University, 2013. https://hdl.handle.net/2144/21139