Back to search

Boston University

Microfluidic evaporator chip for concentration of bacterial samples for SERS identification

Abstract

dc:description.abstract

Sepsis is a serious medical condition in which a person becomes infected with bacteria in his or her bloodstream. The symptoms of sepsis are a result of the immune system’s interaction with the infecting agent. Currently, to diagnose a patient with sepsis, a blood sample must be collected and cultured for 24-48 hours before the infection can be confirmed. In the meantime, a broad-scope antibiotic is administered which may or may not be effective in treating the patient. If the antibiotic is ineffective, a different antibiotic must be chosen. When the results of the blood culture are available, a narrow scope antibiotic, appropriate to treat the infection is administered. However, sepsis has a mortality rate of 18-30% depending on the infecting agent and the treatment is highly time sensitive. Within 24 hours, the syndrome may progress to septic shock and mortality rates reach 50%. Therefore, it is important to quickly and correctly identify the infecting agent and provide immediate targeted treatment. Surface Enhanced Raman Spectroscopy (SERS) can be used to quickly identify and distinguish between different bacterial strains; however it requires higher bacterial concentrations than are present in the blood during the early stages of sepsis. A microfluidic evaporator chip has been developed to concentrate bacteria samples from 4μl to 100nl; the chip has been evaluated for concentration efficiency on Escherichia coli and methicillin-sensitive Staphylococcus aureus. Various blocking methods using bovine serum albumin (BSA) have been tested to reduce bacterial adhesion to the chip and have improved bacterial recovery to around 70% for both strains tested. Ongoing tests are being performed to improve bacterial recovery and sample purity for identification.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Boston University
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Saffie, Jared C.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This work is being made available in OpenBU by permission of its author, and is available for research purposes only. All rights are reserved to the author.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/21248

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Saffie, Jared C.. Microfluidic evaporator chip for concentration of bacterial samples for SERS identification. masters thesis, Boston University, 2014. https://hdl.handle.net/2144/21248