Back to search

Boston University

Validation of MotionWatch8 accelerometer intensity cutpoints in children

Abstract

dc:description.abstract

OBJECTIVE: Excess body weight in children has become a serious public health concern worldwide. The Centers for Disease Control and Prevention (CDC) demonstrated that childhood obesity has tripled since the 1970s in the United States. To prevent childhood obesity, the CDC recommends that children achieve 60 minutes of moderate to vigorous physical activity each day. A variety of wearable monitors are available for objectively assessing activity but these methods are complicated by the lack of established values for the activity intensity and comparability across devices. The purpose of this study is to establish activity intensity cutpoins for the MotionWatch8 (MW8) accelerometer in children by comparison with the gold standard cutpoints established for the Actigraph GT1M accelerometer. MATERIAL/METHODS: 40 children (ages 9-13 years) from Syracuse, NY were enrolled in this study. All participants were required to wear the two different monitors on the dominant wrist as they performed a resting activity (4-minute sitting), a 4-minute slow-paced walk, a 4-minute faster-paced walk, and a 2-minute vigorous running game to mimic the different intensities a child might perform in a free-living environment. Linear regression and receiver operating characteristic (ROC) curves were performed to assess sensitivity and specificity of MW8 intensity cutpoints. RESULT: Mean value for each activity were positively correlated between MW8 and the Actigraph (r=0.85, p<0.001). The optimal cutpoints for differentiating sedentary from light physical activity, light from MVPA, and moderate from vigorous activity were (≤32 counts, ≥ 371.5 counts, and ≥ 859.5 counts per 30 second interval, respectively). CONCLUSION: The MW8 is a simple and objective instrument for measuring physical activity in children. This study provides usable cutoff values for further testing the validity of the MW8 for measuring physical activity patterns among children.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Nutrition and Metabolism
Grantor
Boston University
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lin, Hsuan-Ping

Subjects

dc:subject × 7

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/26887

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Lin, Hsuan-Ping. Validation of MotionWatch8 accelerometer intensity cutpoints in children. masters thesis, Boston University, 2017. https://hdl.handle.net/2144/26887