Abstract
dc:description.abstractRecent advances in high-speed atomic force microscopy (AFM), including new actuator design, advanced controller architecture and overall system optimization have made possible near video-rate imaging of biological samples. Despite this grand achievement, current state-of-the-art high-speed AFM systems still have their limitations, including a small image size and a limited choice of imaging modes. In addition, there are many interesting and important bio-related systems that have dynamics whose time scale is significantly faster than video rate. Thus there is a need to push imaging rates even higher for high-speed AFM systems. In this thesis, we discuss a novel tracking and imaging scheme known as the local raster scan (LRS) method, that can yield an order-of-magnitude improvement or more when imaging a particular class of samples. Local raster scanning utilizes data measured by the AFM system in real-time and steers the tip of the AFM to remain near the sample of interest at all times. LRS is designed for imaging biopolymers or other string-like samples and reduces the overall imaging time, not by increasing the speed of the instrument but by reducing the total sampling area. LRS is achieved by closing a high-level feedback loop around the AFM system. This thesis develops the LRS algorithm, beginning from design of the tip trajectory and moving through the detection schemes that measure the position of the sample in the scan. In addition, this thesis also provide an analysis of the errors of LRS that arise from the noisy measurements of AFM systems and discusses their influence on the performance of LRS. This framework provides a selection guide for choosing LRS parameters so as to maximize the tracking ability of the method. Both simulation and experimental results are included to demonstrate how the LRS performs in practice. These experiments are performed using a combined commercial AFM system together with a modified two-axis nano-positioning stage. The results illustrate improvements of up to an order of magnitude reduction in scan time, compared to the traditional raster scanning scheme with the same resolution and equivalent line rate.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- Boston University
- Year dc:date.issued
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Chang, Peter I.
Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Dc Identifier Barcode
- 11719032088090
- Dc Identifier Bibid
- 99176414280001161
- Dc Identifier Other
- b39007984