Back to search

Boston University

Wearable biosensors to evaluate opioid use in chronic opioid users in the emergency department setting

Abstract

dc:description.abstract

BACKGROUND: It is well known that those taking chronic opioid pain medications often become tolerant to the medications and require escalating doses over time (Drewes, 2017). No objective method to identify tolerance currently exists. OBJECTIVE: The objective of this study is to determine the usability and feasibility of a wearable biosensor technology to determine a transition point between opioid naivety and tolerance. METHODS: Participant’s were recruited in the Emergency Department setting and were being admitted with a treatment plan that includes opioid analgesics. Participants were instructed to wear the sensor at all times and to ‘tag’ the sensor when opioid pain medications were administered. This data was analyzed for trends and changes in sensor data before and after opioid administration. Research staff also conducted formative interviews during and after hospital admission to gather information on the participants’ perception of the wearable biosensor and of opioid tolerance. RESULTS: The sample included 17 participants who received, on average, 21.2 morphine equivalents per day during admission. Over 90% of participants stated that they would wear the sensor again, and 70% would even wear two. Data analysis from the E4 biosensor indicated a difference between baseline physiological signaling and post-opioid administration. CONCLUSIONS: In this study, feasibility of wearable mHealth technology was assured, and the preliminary findings of the biosensor data suggest that the features from activity data at different axes can predict opioid use. Future studies will evaluate the development of tolerance among these participants.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Medical Sciences
Grantor
Boston University
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sweeney, Michael
Advisors dc:contributor.advisor
  • Trinkaus-Randall, Vickery E.
  • Carreiro, Stephanie P.

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/36715

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sweeney, Michael. Wearable biosensors to evaluate opioid use in chronic opioid users in the emergency department setting. masters thesis, Boston University, 2019. https://hdl.handle.net/2144/36715