Back to search

Boston University

Comparison of osseointegration in piezoimplants versus cylindrical implants

Abstract

dc:description.abstract

BACKGROUND: Dental implants have been successful for the restoration of edentulous areas, but current techniques are inadequate in areas lacking sufficient bone volume. Piezoelectric surgery has shown encouraging effects on both osseous healing. A new wedge-shaped titanium PiezoImplant requires piezoelectric osteotomy. This study compares PiezoImplants to conventional threaded cylindrical shaped implants by microcomputed tomography and histology to assess osseointegration, tissue response, and alveolar ridge changes. METHODS: After 3 months post-extraction, 18 conventional cylindrical implants and 18 wedge-shaped PiezoImplants were placed using a split-mouth design in 3 adult mini pigs. The cylindrical implant sites were prepared for osteotomy with rotary instrumentation while the PiezoImplant sites were prepared with piezoelectric surgical inserts. One animal was sacrificed at 4, 8, and 12 weeks post operation. Quantitative µCT and histological analysis evaluated bone volume, osseointegration, and post-operative cellular events. RESULTS: The results of a multivariable linear regression model demonstrated that the PiezoImplants, arch location, and time were significant factors on higher BV/TV percentage. Bone to implant contact (BIC) analysis by high resolution microscopy and histomorphometry indicated osseointegration though intimate contact between implants and adjacent alveolar bone in both groups. The tissue response displayed no evidence of abnormal healing and the PiezoImplant was classified as a non-irritant. CONCLUSION: The combination of piezoelectric osteotomy and newly designed PiezoImplants had favorable effects on wound healing and osseointegration compared to conventional cylindrical implants. These novel wedge-shaped implants may be beneficial for narrow ridge spaces without additional ridge augmentation. Further research is needed to establish clinical validity.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Design
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Periodontology
Grantor
Boston University
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fujinaka, Trevor
Advisor dc:contributor.advisor
  • Dibart, Serge

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/37058

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Fujinaka, Trevor. Comparison of osseointegration in piezoimplants versus cylindrical implants. masters thesis, Boston University, 2019. https://hdl.handle.net/2144/37058