Back to search

Boston University

Sensor-enabled and multi-parametric evaluation of drug-induced nephrotoxicity in a kidney-on-chip

Abstract

dc:description.abstract

Many drugs and environmental chemicals, such as antibiotics and chemotherapeutic agents, are nephrotoxic (toxic to the kidney) and are a common cause of acute kidney injury and chronic kidney disease. Conventional tissue models for assessment of drug-induced nephrotoxicity rely on animals or simple cell culture models, which lack tissue characteristics of the human kidney required to accurately predict a drug’s effect in clinical trials. Microfluidic kidney-on-chips can generate tissue with improved human relevance compared to traditional models, however, generally lack high-throughput and multiparametric data collection capabilities for evaluation of nephrotoxic drug exposures. Standard data collection techniques remain limited to fluorescent imaging or colorimetric assays that often focus on single endpoints, are invasive due to the addition of labels, and fail to capture dynamic changes in tissue function. Additionally, conventional toxicological readouts rely on bulk measures of injury, such as cell death, which are less sensitive than sub-lethal changes in cell function and morphology that occur prior to cell death. Due to the challenges above, there is a need for new measurement approaches that enable collection of kinetic, multi-parametric, and sub-lethal readouts of injury in kidney-on-chip systems. In this work, we developed and characterized several measurement approaches for evaluation of tissue function in kidney-on-chip systems and assessment of drug-induced nephrotoxicity. In chapter 2, we developed a novel optical-based oxygen sensing technique for measurement of sub-lethal mitochondrial dysfunction in an array of kidney-on-chips. In chapter 3, we investigated an approach for simultaneous transepithelial electrical resistance (TEER) sensing and flow control to enable near-continuous monitoring of tissue barrier function under different flow conditions. In chapter 4, we demonstrated the use of different data collection modalities, including multiple sensors, fluorescent imaging, and colorimetric-based assays, to generate multi-parametric readouts for evaluation of drug-induced nephrotoxicity in kidney-on-chips.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor
Boston University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kann, Samuel Harris
Advisors dc:contributor.advisor
  • Zhang, Xin
  • Vedula, Else M.

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/46253

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kann, Samuel Harris. Sensor-enabled and multi-parametric evaluation of drug-induced nephrotoxicity in a kidney-on-chip. doctoral thesis, Boston University, 2023. https://hdl.handle.net/2144/46253