The current tools used in transcatheter procedures for interventional cardiology are often limited to one or two degrees of freedom as well as in their distal control, dexterity, and force output. These shortcomings greatly restrict which procedures can be translated from open-heart to transcatheter methods. To address these shortcomings, Rogatinsky et al. of the Morphable Biorobotics Laboratory (MBL) developed an interventional robot comprising a soft stacked balloon actuator (SBA) manipulator and a pop-up stabilization mechanism. The stabilization plays a critical role for the robot by moving the device fulcrum closer to the procedure site as well as creates a fixed reference point for the soft manipulator. The stabilization allows for greater mechanical leverage, force transmission, and predictable, controllable movement. This thesis draws inspiration from the stabilization mechanism from Rogatinsky et al. and presents a new stabilization design that can be successfully deployed in in vivo tests. This new design bears a segmented backbone, new pop-up geometry, different material, and an intuitive actuation system. This overall design allows the robot to navigate vasculature curves, make it robust against the unpredictability of the in vivo setting, increase the device’s mechanical and deployment failure threshold, and limit user error, respectively while matching and outperforming the initial design in respect to axial and radial perturbation resistance, and absence of vessel occlusion. These results allow the overall prototype to complete in vivo tests, a necessary step for product development toward clinical viability.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor
Boston University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Matthews, Grace A.
Advisor dc:contributor.advisor
  • Ranzani, Tommaso

Subjects

dc:subject × 8

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/49703

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Matthews, Grace A.. Nitinol stabilization device for beating-heart procedures. masters thesis, Boston University, 2025. https://hdl.handle.net/2144/49703