Back to search

Boston University

Multi-wavelength multi-distance approach for evaluating the metabolic activity of the brain in diffuse correlation spectroscopy and wearable near infrared spectroscopy

Abstract

dc:description.abstract

The adult human brain, despite comprising only 2% of our total mass, is responsible for roughly 20% of our total energy consumption. In healthy individuals, cerebral autoregulation maintains consistent blood flow to meet the brain’s high metabolic demands, even during systemic fluctuations. However, in vulnerable populations such as neonates—particularly those at risk of brain injury—this regulatory mechanism may be impaired, underscoring the need for non-invasive, continuous monitoring of cerebral oxygenation and metabolism. Optical imaging modalities such as near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS) are emerging non-invasive tools capable of continuous monitoring of cerebral parameters such as oxygenation and blood flow. In this thesis, I present the development and validation of two novel, multi-wavelength (MW) optical systems for monitoring cerebral metabolism in neonates. The first is a MW multi-distance DCS system, designed to estimate the cerebral metabolic rate of oxygen (CMRO₂) by combining blood flow and oxygenation measurements. The second is the MW FlexNIRS, a wearable, wireless NIRS device capable of resolving changes in mitochondrial metabolism by tracking concentration changes in oxidized cytochrome c oxidase in addition to oxy- and deoxyhemoglobin. To complement this device a wavelength-weighted algorithm was developed to account for the broad LED emission profiles and photodiode responsivity. We performed extensive validation for both devices and show preliminary clinical data obtained on infants. These systems represent key steps toward accessible, non-invasive, real-time monitoring of cerebral metabolic health in the neonatal intensive care setting.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor
Boston University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Otic, Nikola
Advisors dc:contributor.advisor
  • Boas, David A.
  • Franceschini, Maria Angela
ORCID dc:identifier.orcid

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • Attribution 4.0 International
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/50595

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Otic, Nikola. Multi-wavelength multi-distance approach for evaluating the metabolic activity of the brain in diffuse correlation spectroscopy and wearable near infrared spectroscopy. doctoral thesis, Boston University, 2025. https://hdl.handle.net/2144/50595