Back to search

Boston University

A comparison of automated and manual sperm detection in low sperm samples

Abstract

dc:description.abstract

The detection and identification of biological fluids is an important aspect of forensic investigation. The detection of semen commonly holds probative value in sexual assault-type cases involving male perpetrators. The general workflow for forensic analysis of semen consists of an initial presumptive test, followed by a more specific test. Currently, many crime laboratories confirm the presence of semen by conducting manual microscopic examinations for sperm on stained slides. With the existing sexual assault kit backlog, this time and labor-intensive procedure does not offer the desired efficiency in analysis. Thus, the forensic field may benefit from the implementation of artificial intelligence and automated microscopy for increased efficiency in sperm detection. To investigate this, the study presented here compared slide examinations of mock sexual assault samples using an automated microscope with the MetaSystems Metafer Sperm Detection software to manual examinations conducted by crime laboratory analysts. To mimic cases with low sample quantity and/or high levels of degradation, slides with minimal or no sperm cells were prepared in combination with varying levels of additional cellular material or debris. The scan times and sperm counts were collected for both examination types, and participating analysts answered questionnaires regarding their experience levels and typical laboratory procedures. Overall, the results demonstrated that the MetaSystems microscope was able to complete an entire scan at least 4 minutes faster than a manual search (4:26 faster for Set 1, 8:20 faster for Set 2). On average, analysts made their first sperm cell identification within 2 minutes and their total sperm counts corresponded with the automated counts. Therefore, the results demonstrate that while the automated and manual searches have about the same detection capability, the MetaSystems microscope was able to reach the same conclusions faster. Furthermore, an image of each potential sperm cell detected is saved and scored by the software for easy reference by the user. This system offers a promising tool for efficiently locating and documenting sperm and facilitating a reduction in the sexual assault kit backlog faced by many crime laboratories.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Anatomy & Neurobiology
Grantor
Boston University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Toledo, Doris
Advisor dc:contributor.advisor
  • Brodeur, Amy N.

Subjects

dc:subject × 8

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/52384

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Toledo, Doris. A comparison of automated and manual sperm detection in low sperm samples. masters thesis, Boston University, 2025. https://hdl.handle.net/2144/52384