Boston University
Metallosis following prosthetic joint replacement: pathophysiology, clinical complications, and contemporary treatment strategies
Abstract
dc:description.abstractMetallosis is defined as the accumulation and deposition of metallic debris in the soft tissues of the body, most commonly resulting from the corrosion of metallic implants following total joint replacement surgery. This condition is one of the primary causes of patients requiring a revision of the prosthesis, which can be a stressful and expensive procedure. Metallosis arises from micromotion, or the constant oscillatory contact between two parts of the implant at an interface, which corrodes the surface of the implant and produces metal particles. These particles can infiltrate surrounding tissue and enter the bloodstream. If left untreated, metallosis can lead to inflammation, breakdown of bone, nerve damage, cognitive defects, and problems in other vital organs such as the heart. This study examines the current diagnosis and treatment pathways for this condition, along with ongoing research evaluating new methodologies and technologies that could be utilized in the future to improve patient outcomes.Diagnosis of metallosis involves using radiographing imaging in conjunction with CT scans and MRI to detect prominent symptoms of metallosis, from metal debris to osteolysis to the formation of pseudotumors. The most critical evidence required for a diagnosis is the detection of elevated metal ion levels in circulation, as measured by a blood test. Additionally, if the patient presents with a biopsy of periprosthetic tissue, it could reveal further information, including the degree of inflammation and necrosis present within the tissue. Once diagnosed, the current standard for treatment is revision surgery, where an orthopedic specialist will remove any necrotic or diseased tissue, clean up the implant and surrounding bone, and, lastly, install a new prosthetic into the patient. The replacement prosthetic may be designed to have a different composition comprised of the original implant due to sensitivity to the previous implant materials. Separately, there is evidence to suggest that several non-invasive treatments could be utilized as an additional therapeutic option for metallosis treatment. Chelation therapy has been proven effective in reducing the circulating metal ion content in metallosis patients. Meanwhile, various pharmaceutical agents have been developed to counteract the effects of osteolysis by inhibiting the bone-resorption activity of osteoclasts, potentially stabilizing the affected joint for a more extended period of time. However, to avoid the requirements for these treatment options, the highest priority is to develop standardized practices and tools that can significantly reduce the risk of metallosis occurrence in the first place. The first consideration is the utilization of different materials in implants instead of the standard metal-on-metal prostheses. While the most common alloy used to make implants is cobalt-chromium, other models using titanium and stainless steel have been considered due to variations in elasticity, corrosion resistance, and cost. On the other hand, implants with ceramic heads are frequently used due to their high biocompatibility and the fact that they do not release metal debris. However, ceramics are far more brittle and can create squeaking noises during ambulation, which can be problematic for the patient. Additionally, polyethylene liners have been added to the joint interface in a prosthesis, reducing friction and contact between two surfaces. While these liners cannot be applied at all interfaces of the implant, they have been helpful in reducing the formation of metal debris. The second consideration for preventing metallosis is to utilize tools and techniques that minimize aseptic loosening during the assembly of the prosthesis. With a taper interlock assembly toolkit, an orthopedic surgeon can align each piece of the prosthesis at the exact same angle, ensuring there is no degree of misalignment and preventing micromotion. Vibratory insertion devices offer a method for inserting implants into bone with higher precision and reduced physical strain on both the surgeon and patient. Finally, robotic-assisted surgery systems can aid physicians in planning the size and dimensions of the implant, mapping out the surgical plan, and increasing accuracy during insertion. While current diagnostic tools and revision surgeries help manage metallosis, prevention remains the most effective approach to managing this condition. Advances in implant materials, surgical techniques, and robotic-assisted systems show promise in reducing the risk of metal debris formation. The best treatment option would combine biocompatible implants with the highest resistance to corrosion, along with techniques that maximize precision during surgery, such as vibratory insertion and robotic-assisted surgery. Advancements in chelation therapy and medications to inhibit bone decay can be beneficial as secondary treatment options. However, more research is needed to refine these technologies and develop standardized guidelines that can reliably prevent metallosis and improve long-term patient outcomes.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Medical Sciences
- Grantor
- Boston University
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Daita, Aditya
- Advisors dc:contributor.advisor
-
- Trinkaus-Randall, Vickery
- Nielsen, Marisa
- ORCID dc:identifier.orcid
Subjects
dc:subject × 8Rights
dc:rights- Statement dc:rights
-
- Attribution 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2144/52783