Boston University
Development and optimization of a synthetic cannabinoid identification mode via a portable Mass Spectrometer
Abstract
dc:description.abstractIllicit drug use pertaining to synthetic cannabinoids has been on the rise in the United States since they were introduced in the early 2000s. As a result, forensic laboratories across the nation have experienced a dramatic increase in caseloads and continue to battle the analytical challenges that come with emerging drugs. One solution to address these issues is the application of portable instrumentation to aid in on-site detection. This provides faster results and can help eliminate drug evidence sent to laboratories. Synthetic cannabinoids (SCs) are lab-manufactured substances designed to mimic the effects displayed in naturally grown cannabinoids. They are structurally similar to the main psychoactive component of cannabis, delta-9-tetrahydrocannabinol (d9-THC), but their differences make them more potent than naturally grown cannabis. Their increased potency and toxicity have resulted in a public health crisis and constant emergency federal scheduling of the substances. Emergency scheduling is also in part due to the rapid evolution where minute changes are made to the molecular structures of synthetic cannabinoids to avoid legal repercussions, causing laboratories and lawmakers to struggle with staying up to date on emerging substances. During this research, the MX908, a field portable High-Pressure Mass Spectrometer (HPMS), was used to expand the library of targets to include ADB-BUTINAATA, ADB-FUBINACA, MAB-CHMINACA, MMB-CHMICA, and MMB-FUBICA in the Drug Hunter mission mode. Once these targets were created and added to the on-device library, a method validation study was conducted to assess their performance. Overall, the synthetic cannabinoids correctly alarmed for the JDXs built 21 out of 25 times (84.0%). Additionally, eleven pre-existing targets underwent aperture voltage optimization that tested a range of voltage parameters to achieve optimal fragmentation. Ultimately, a selection of aperture voltage values was chosen and compared to the established parameters and fragmentation employed by the instrument in the Drug Hunter mission mode. Based on the data, it was found that a combination of 15, 50, 70, and 120 V would be most suitable for synthetic cannabinoid analysis.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Forensic Sciences
- Grantor
- Boston University
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Simmons, Madison Renee
- Advisor dc:contributor.advisor
-
- Hall, Adam B.
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2144/53202