Back to search

Boston University

Assessing the clinical viability of one- and two-piece zirconia implants as alternatives to titanium-based restorations in the anterior mandible

Abstract

dc:description.abstract

OBJECTIVES: To compare the biomechanical stress distribution and optical performance of titanium, two-piece zirconia, and one-piece zirconia implant systems at the mandibular central incisor. MATERIALS AND METHODS: Three finite element models were constructed for each implant system, restored with a multilayer zirconia crown (LayZir) transitioning from 3Y-TZP cervically to 5Y-PSZ occlusally. A physiological oblique load of 10.1 N was applied palato-labially. Von Mises stress was evaluated across implant components and surrounding bone. Crown optical behavior was characterized by contrast ratio measurement across five clinically derived thicknesses (0.60–1.45 mm) in three compositional layers. RESULTS: The titanium system recorded the lowest peak von Mises stress, followed by one-piece zirconia, with two-piece zirconia generating the highest concentrations. Contrast ratio increased monotonically from 0.684 (5Y-PSZ enamel layer, 0.60 mm) to 0.906 (3Y-TZP dentin layer, 1.45 mm), a span of ΔCR 0.222 exceeding the 0.06 clinical perceptibility threshold by a factor of 2.5. No measured crown thickness reached the 1.5 mm minimum required to mask a titanium implant substrate. CONCLUSIONS: The titanium system most closely approximated physiological stress distribution, demonstrating the greatest loading uniformity across implant and bone. Zirconia implants, while generating higher stress concentrations, eliminate the optical liability of metallic substrate show-through at the translucent incisal zone — a limitation inherent to titanium that persists independent of crown material. Implant system selection in the anterior esthetic zone should therefore weigh biomechanical performance and optical substrate compatibility as independent clinical determinants.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Design
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Restorative Sciences & Biomaterials
Grantor
Boston University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Khuzam, Maher
Advisor dc:contributor.advisor
  • Tsouknidas, Alexandros

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/53317

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Khuzam, Maher. Assessing the clinical viability of one- and two-piece zirconia implants as alternatives to titanium-based restorations in the anterior mandible. masters thesis, Boston University, 2026. https://hdl.handle.net/2144/53317