Boston University
Quadrupole time-of-flight validation method for forensic toxicology testing
Abstract
dc:description.abstractThis thesis aims to demonstrate how the validation of a new analytical method for a liquid chromatograph-quadrupole time-of-flight-mass spectrometer (LC-Q-ToF-MS) is achieved for the purpose of forensic toxicology qualitative method. A validation plan was co-authored based on American National Standards Institute/Academy Standards Board (ANSI/ASB) Standard 036, First Edition, Standard Practices for Method Validation in Forensic Toxicology with the purpose of outlining the steps to take while performing a full validation of a screening method for blood, serum, and urine. The following studies were selected as part of the validation: ionization suppression/enhancement, interferences study, carryover studies, sample stability, and limit of detection. The Rhode Island Department of Health Forensic Toxicology Laboratory (RIDOH) amended their current scope of testing to include analytes with the recommended limits of detection by ANSI/ASB Standards 119, 120, and 121. These included cannabinoids, opioids, central nervous system (CNS) stimulants, barbiturates, benzodiazepines, tricyclic antidepressants (TCAs), anticonvulsants, CNS depressants, dissociative anesthetics, over-the-counter (OTC) medications, and structurally related analogues. This paper also discusses how successful screening method validation will replace their current Gas Chromatography-Mass Spectrometry (GC/MS), Tecan Freedom Evo® enzyme-linked immunosorbent assay screening, and details its advantages as a replacement, with preliminary data supporting this hypothesis, as well. This new instrumentation and screening method will also provide more effective support in aiding the Office of State Medical Examiner (OSME) in death investigations, Drug Facilitated Sexual Assaults (DFSAs) investigations and Driving Under the Influence (DUI) and Driving while Under the Influence of Drugs (DUID) law enforcement. Prior to performing the method validation, a proof of concept was conducted, to ensure the experimental design worked with the set parameters for the instrument. Samples were prepared using a solid phase extraction method. This validation is currently in progress, but preliminary observations after completion of the interference study suggest that the analytical and experimental parameters developed are ideal for this instrument and for the purpose of forensic toxicology testing.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Forensic Sciences
- Grantor
- Boston University
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Staufacar, Beatriz Rosenthal
- Advisor dc:contributor.advisor
-
- Wareing, Celeste M.
- ORCID dc:identifier.orcid
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- Attribution 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2144/53465