Boston University
Influence of human osteoblasts on biological and mechanical properties of zirconia implant materials
Abstract
dc:description.abstractZirconia implants have been introduced as non-metallic alternatives to titanium implants because of their favorable esthetics, biocompatibility, corrosion resistance, and tooth-like appearance. However, zirconia implant materials differ in composition and microstructure, which may influence both biological behavior and mechanical performance. The purpose of this in vitro study was to compare 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) and alumina-toughened zirconia (ATZ) implant materials with respect to normal human osteoblastic cell activity and biaxial flexural strength. Disc-shaped specimens were fabricated from 3Y-TZP and ATZ powders, sintered according to manufacturer recommendations, and surface-treated using airborne-particle abrasion, acid etching, and plasma treatment. Surface morphology was qualitatively evaluated using scanning electron microscopy. Normal human osteoblastic cells were cultured on the zirconia specimens, and biological response was assessed by attachment efficiency, proliferation, osteocalcin expression, and SEM-based cell morphology evaluation. Biaxial flexural strength was tested using a piston-on-three-ball method after exposure to air, culture media, or osteoblast culture conditions. Statistical analysis was performed using analysis of variance with post hoc comparisons, with significance set at P < 0.05. Both zirconia materials supported normal human osteoblastic cell attachment and spreading. SEM evaluation demonstrated cellular attachment, cytoplasmic extensions, and increased surface coverage over time on both 3Y-TZP and ATZ specimens. Cell attachment was favorable on both zirconia materials compared with the control condition. Proliferation on zirconia specimens was lower than control at later time points, while no significant difference was observed between 3Y-TZP and ATZ. Osteocalcin expression did not differ significantly among the zirconia and control groups, suggesting comparable late osteoblastic differentiation behavior under the tested conditions. Biaxial flexural strength was significantly influenced by material type, with 3Y-TZP (910.78 MPa) demonstrating higher strength than ATZ (698.22 MPa). Exposure to culture media or osteoblasts did not significantly affect flexural strength. Within the limitations of this in vitro study, both 3Y-TZP and ATZ demonstrated biological compatibility with normal human osteoblastic cells; however, their mechanical performance differed. These findings support the need to evaluate zirconia implant materials using both biological and mechanical outcomes.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Science in Dentistry
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Prosthodontics
- Grantor
- Boston University
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bajaj, Akshar
- Advisor dc:contributor.advisor
-
- Giordano, Russell
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2144/53684