Back to search

State University of New York at Buffalo

Resolution Adaptation and Secondary Optimization of Volumetric Modulated Arc Therapy

Abstract

dc:description.abstract

Volumetric modulated arc therapy (VMAT) combines good radiation dose performance, in terms of target coverage, with increased speed-of-delivery, as compared with competing forms of intensity modulated radiation therapy. A VMAT plan is produced by solving an optimization problem using dose-volume objectives. The objectives are defined for the volumes representing targets and radio-sensitive organs. The multi-leaf collimator (MLC), an electro-mechanically controlled shielding device composed of thin tungsten leaves, allows VMAT to be delivered. The apertures in the VMAT plan are defined using the MLC. We investigated two methods of changing VMAT apertures for clinical benefit. In the first, pre-existing patient plans (optimized to be delivered on a linear accelerator equipped with a high-definition multileaf collimator) were adapted to be deliverable on a treatment machine equipped with a standard-definition MLC. The leaf positions defining individual apertures (high-definition) were adapted to the standard definition MLC. A study of adapted plans was performed to assess the feasibility of delivering the adapted plans for a portion of the treatment course. In the second method, a system was developed to perform a post-optimization step that operates on a pre-existing VMAT plan. The software system was used to search for improvements to a test--bed plan, by perturbing VMAT apertures, and updating the dose via pre-computed, Monte Carlo calculated, beamlets.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • French, Samuel
Contributors dc:contributor
  • Nazareth, Daryl
  • Radiology

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
  • Copyright retained by author.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/79854

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

French, Samuel. Resolution Adaptation and Secondary Optimization of Volumetric Modulated Arc Therapy. State University of New York at Buffalo, 2019. http://hdl.handle.net/10477/79854