State University of New York at Buffalo
Detection and Monitoring of Multiple Myeloma Measurable Residual Disease by High Sensitivity Flow Cytometry
Abstract
dc:description.abstractThe ability to identify residual myeloma cells (e.g. measurable residual disease; MRD) can provide valuable information pertaining to a patient's depth of response to therapy and risk of relapse. Multiparametric flow cytometry (MFC) is an excellent technique to monitor MM MRD and has been demonstrated to correlate with patient outcomes post-treatment. The implementation of MFC as a clinically useful assay for MRD testing faces several obstacles and these include: (i) the need to employ a high sensitivity flow cytometric assay as conventional staining methods are not optimized to process and acquire large numbers of cells; (ii) the administration of antibody-based immunotherapy such as daratumumab can hampered the detection of CD38 on PCs; and (iii) the lack of a standardized approach for a flow cytometric data analysis causes major heterogeneity in MM MRD analysis and interpretation. We set out to address these issues in this study.To achieve the high sensitivity (one abnormal cell in 105 − 106 cells) required for MRD evaluation, millions of cells have to be acquired and conventional immunophenotyping protocols are unable to attain these numbers, indicating the need for alternative flow cytometric staining procedures. A bulk, 'Pre-lysis' method is the current consensus approach for staining large number of cells; it requires two red blood cell lysis steps which can adversely affect epitope density. In this study, we tested the 'Pooled-tube' and 'Dextran Sedimentation' staining procedures and correlated them with the 'Pre-lysis' method as potential alternative approaches. The second goal of this study is to address the impact of immunotherapeutic intervention that employed antigen-specific drugs on the detection of PCs by MFC. Daratumumab is an anti-CD38 immunotherapeutic drug that has increasingly been used to treat patients with heavily pre-treated and relapsed/refractory MM. In so doing, the detection of CD38 antigen on PCs by MFC is unnecessarily impeded, and alternative markers that can be used in place of or in addition to CD38 antibody for detecting plasma cells are urgently needed. This study evaluated the expression profiles and stability of 16 alternative markers on PCs. The ability of selected markers to detect PCs were further evaluated in BM samples treated ex vivo with daratumumab. Our third goal is to address the inconsistencies of flow cytometric data analysis and interpretation in MM MRD testing due to the current lack of a standardized approach. As an increasing number of laboratories are adopting MFC for MM MRD testing, the implementation of a standardized approach to ensure reproducibility of test results is important. We hypothesized that a standardized analysis approach can be implemented to reduce variations seen with flow cytometric data analysis and reporting...Taken together, our study addressed some of the most important considerations when implementing MFC for MM MRD testing. Our study established and validated both 'Pooled-tube' and 'Dextran Sedimentation' staining procedures as alternative high sensitivity flow cytometric assays to 'Pre-lysis' that are suitable for MM MRD testing. For circumventing the issue with the detection of CD38 by MFC when daratumumab is administered, we determined CD319 (SLAMF7) to be the most suitable alternative because (i) it produced the best separation between PCs and other contaminating hematopoietic cells, (ii) it was stably expressed by PCs despite prolonged storage at 4oC, and (iii) elotuzumab (clone 162.1) did not interfere with plasma cell detection. Our results showed that a panel used for monitoring MM MRD could be modified by combining CD38 and CD319 into the same detection channel to detect PCs in daratumumab or elotuzumab treated patients. Finally, to improve the reproducibly of MM MRD testing by MFC, we created a consensus document that detailed standardized flow cytometric gating approaches and analysis strategy for handling MM MRD data files. We found that the adoption of a harmonized data analysis approach can reduce result discrepancies between different laboratories.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2020
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Soh, Kah Teong; 0000-0002-0146-0485
- Contributors dc:contributor
-
- Wallace, Paul
- Roswell Park
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Copyright retained by author.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/86938