Background: Intraoral scanning (IOS) of complete arches is a challenging aspect of clinical dentistry. The accuracy of IOS is vital to ensure a clinically acceptable restoration. Given the rapid advance and integration of digital technology into the profession, evaluating the clinical outcome of definitive restorations produced with a digital workflow is crucial. The purpose of this study was to compare the impact of three intraoral scanning strategies on the clinical outcomes for a tooth-borne full-mouth rehabilitation. Materials and Methods: Full-mouth restorations were manufactured using three distinct protocols. Dentiforms mounted on semi-adjustable articulators and their associated interim restorations were used. An intraoral scanner (TRIOS 3; 3Shape A/S) was used to record digital impressions using two scanning strategies (n=5 for each scanning strategy). A desktop scanner was used to record complete arch scans (n=5) as a control group. Restorations were designed following the contour of interim restorations, then fabricated from monolithic zirconia using a 5-axis milling machine. One way-ANOVA followed by Tukey Honestly Significant Difference tests were used for statistical analysis to compare the number of images, length of scanning time, and the opening of the incisal pin between all the groups. In addition, the Kruskal-Wallis test, followed by Dunn’s multiple comparisons test, were used to compare the marginal integrity, interproximal contact, and occlusal contacts between the protocols. Results: Protocol B had a significantly higher number of images compared to Protocol A anterior and posterior (p < 0.001). There was a significant variance in scanning time between the protocols (p < 0.001). Protocols A and C produced significantly better interproximal contacts than protocol B. Conclusions: While each of the three protocols produced clinically acceptable outcomes after adjustment, only Protocol A is a recommended chairside workflow for complete-arch rehabilitation. Protocols B and C produce restorations which require mounting on a semi-adjustable articulator for extensive adjustment, making them poor choices for clinical use.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Elsayed, Bara
Contributors dc:contributor
  • Sadid, Ramtin
  • Oral Sciences

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
  • Copyright retained by author.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/87614

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Elsayed, Bara. Impact of Scanning Protocol on the Clinical Outcome of Tooth-Borne Complete Arch Rehabilitation. State University of New York at Buffalo, 2021. http://hdl.handle.net/10477/87614