State University of New York at Buffalo
Streptococcus mutans Differential Retention on Dental-Related Substrata
Abstract
dc:description.abstractBiofilms account for 80% of all infections in the human body. Dental plaque is the result of the accumulation of an oral biofilm on the enamel tooth surface. Oral actinomyces and streptococci species are the primary colonizers and initiate oral biofilm production. Streptococcus mutans are the main causative species of carious lesions. Oral prosthetics are becoming more frequently used as modern society has put an emphasis on maintaining the oral health. Removable partial dentures and abutments are two prosthetics that are used with surrounding, intact tooth structure. Two polymers used in clinical settings to fabricate these oral prosthetics are polymethyl methacrylate (PMMA) and polyether ether ketone (PEEK).This thesis research investigated viable Streptococcus mutans retention on different substrata after varying saline rinses. The two substrata investigated were polymethyl PMMA and PEEK, and germanium prisms were used as a reference material to an in vitro model of tooth enamel structure. Coupons were placed into cell suspensions and incubated (37° C; 5% CO2) for either 4-hours or 24-hours. After incubation, each coupon was first “gentle rinsed” with normal saline (0.9% NaCl), and then rinsed with a more rigorous Waterpik® Waterflosser. Colony Forming Units (CFUs), comprehensive contact angle analysis, Multiple-Attenuated Internal Reflection Infrared Spectroscopy (MAIR-IR) and Scanning Electron Microscopy (SEM) were all used to analyze S. mutans removal and retention from the surface of the three experimental substrata. Based on the data, significantly more S. mutans remained on the PEEK coupon surfaces compared to PMMA coupon surfaces for both 4-hour and 24-hour incubation periods (p=0.0036 and p=0.0002, respectively). Even after the sequential gentle and Waterpik® rinses, MAIR-IR technique confirmed a protein layer remained on germanium prisms for both 4-hour and 24-hour experiments. Contact angle analysis demonstrated that even after both rinses were performed, PEEK and PMMA sample surfaces had higher polarity than what was measured before bacterial exposure. The increase in polarity was indictive of biofilm remaining on the material surfaces, which was supported by MAIR-IR results from germanium prisms. SEM images confirmed that PEEK samples had scratches with ranging widths of 0.5 µm – 2.0 µm. Further studies need to be performed to investigate whether these scratches are correlated to the higher numbers of viable cells remaining on PEEK coupons compared to PMMA coupons.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Tardibuono, Anthony
- Contributors dc:contributor
-
- Meyer, Anne
- Biomaterials
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Copyright retained by author.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/87687