State University of New York at Buffalo
Modeling HD MLCs in EGSnrc for Monte Carlo Simulations With Applications to CBCT-Based Inter-Fraction Dose Tracking in Radiotherapy
Abstract
dc:description.abstractPurpose: To develop a phase-space based, high definition multi leaf collimator(HD MLC) model TrueBeam accelerator for use in both Computed Tomography (CT) and Cone Beam Computed Tomography (CBCT)-based VMAT Monte Carlo (MC) dose calculations. In addition, to develop a method using CBCT images to evaluate dosimetric changes through different fractions of patient’s treatment course. Methods: Using the EGSnrc MC software toolkit, a TrueBeam accelerator module was designed to support the use of phase space files as a particle source and high definition MLC leaves as downstream patient plan specific collimators. Dimensions for the jaws were coded using our previously defined Varian Trilogy X and Y jaws. Dimensions for the HD MLCs were determined by a trial and error process, along with generic data obtained from investigators at McGill University. Phase space files were provided by Varian Medical Systems and validated by generating standard beam profiles in water and comparing to data from our Treatment Planning System (TPS). To minimize latent phase space variance, a concatenated phase space approach was used. Calibration factors for scaling MC dose to absolute dose were derived for 4 energies. Scans of a 32x36x36 cm3 tank filled with water, a 30x30x30 cm3 cube of solid water and Catphan image data were employed to calibrate our MC ramp function used for generating patient phantoms for two CBCT data acquisition modes: Pelvis and Thorax. A clinical study involved 2 prostate patient (post prostatectomy) treatment courses.6 fractions for the first plan and 5 fractions for the second were investigated using CBCT images acquired on the days of treatment. Images were first selected for scan quality and imported into Eclipse TPS. The CTV, bladder and rectum were contoured on each CBCT image set by a Radiation Oncology resident. Fields from the original plan were copied over to each CBCT plan. The DICOM image offset in the original plan was used to align the field isocenters in each CBCT plan. Plans were then created with 3D translations applied to the treatment isocenters to reflect couch shifts on the day of treatment. Doses to the OARs and the CTV were then analyzed…Conclusion: The scope of our MC VMAT dose calculation system was greatly expanded with the development of the TrueBeam accelerator model and CBCT-based calculation capability as well. Results from the prostate clinical study indicate that dose to OARs as well as bladder volume can change significantly during a treatment course, though these are subject to inter-contour variability and other limitations. MC calculations on CBCT images may be used to verify Eclipse calculations, as a possible use case. Future research applying Enhanced Optimization to Adaptive Radiation Therapy may use this work as a foundation.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bhagroo, Stephen
- Contributors dc:contributor
-
- Nazareth, Daryl
- Radiology
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Copyright retained by author.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/87753