State University of New York at Buffalo
Comparison of Scanning Accuracy of PVS Impressions of Multiple Tooth Preparations with Different Tapers Using Two Benchtop Scanners: An In-Vitro Study
Abstract
dc:description.abstractIntroduction: The all-ceramic-crown manufacturing techniques have evolved significantly since the very first porcelain jacket crown was introduced by Dr. Charles Land in 1903 1. With the advancement in computer-aided design and computer-aided manufacturing (CAD CAM) technologies, along with new dental materials development, more and more all-ceramic-crowns are produced through a digital workflow rather than manually. There have been studies comparing marginal discrepancies of all-ceramic crowns generated through different pathways, including CAD CAM workflow (intra oral scanning, extra oral model or negative VPS (Vinyl Polysiloxane) impression scanning), or manual hot-pressing techniques 2. However, there is lack of data concerning scanning accuracy for negative VPS impressions with multiple tooth preparations. Materials and Methods: Two different occlusal convergence angles (12 and 24 degree) full arch typodont models with multiple all-ceramic crown tooth preparations were digitally designed and 3D printed. Their respective VPS impression were then taken. Two benchtop scanners, D2000 and E4 (3Shape, Copenhagen, Denmark), were used to scan the impressions 10 times each. The reference models were scanned by the E4 scanner. The STL files of the reference model and its corresponding impression scan were superimposed using Geomagic Control X 2020 software. The absolute average deviation measured in µm were compared in a total of 16 subgroups relating to scanners, tooth locations and convergence angles. Three-way ANOVA and post-hoc Tukey HSD pairwise comparison tests were conducted. A non-parametric Kruskal-Wallis test was also performed to confirm Tukey HSD test results. Results: The absolute maximum deviation (AMD) of the VPS impression scan compared with its reference model was 88.5 µm, and the largest absolute average deviations (AAD) ranged 45.6 88.5 µm were observed in the 12 degree convergence angle impression of the molar site using the D2000 scanner. The AAD for the other 15 subgroups were under 30 µm. Scanning accuracy of negative VPS impressions are significantly different by the scanners used, by tooth locations and the occlusal convergence angles. However, the scanning accuracy of the VPS impression appeared to generate clinically acceptable all ceramic crowns with marginal discrepancies under 150 µm. Conclusion: Although, statistically significant differences exist between scanners, among different tooth locations and different occlusal convergence angles, the accuracy of negative VPS impression scans appears to be adequate for generating clinically acceptable all-ceramic crowns.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zhang, Jinghua
- Contributors dc:contributor
-
- Kim, Hyeongil
- Oral Sciences
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Copyright retained by author.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/87756