Back to search

State University of New York at Buffalo

Design and Numerical Investigation of RF Transceiver Arrays for 7T MR Imaging in Humans

Abstract

dc:description.abstract

Magnetic resonance imaging (MRI) is a non-invasive medical imaging modality used extensively in clinical and research settings to image the interiors of human body. The MRI technique focuses on improving image quality, achieving the best possible tissue contrast, and maximizing the SNR (signal-to-noise ratio). Modern magnetic resonance devices employ phased array coils made of low impedance resonant loops. Electrodynamic interactions between elements in such arrays must be carefully balanced. To mitigate inductive coupling, neighboring coil components are strategically overlapped, and preamplifier interfaces are tuned to suppress the induced current on each element. We use COMSOL Multiphysics to develop various RF coils for a variety of MRI applications. The computational simulation, viability, and efficiency were validated, and the absolute SNR and better decoupling performance will be provided. Firstly, we have designed a 4-channel catheter Radio Frequency coil array for endovascular MR imaging at 7T. Interventional magnetic resonance imaging (MRI) devices has been shown with a new 4-channel RF catheter coil design with a better field of view (FOV) and maximum proximity. The unique design of the proposed 4-channel catheter coil array possesses intrinsic decoupling performance among all 4 resonant elements. This catheter coil was designed to attain parallel imaging capability simultaneously providing required B1 fields and intrinsic decoupling among the resonant elements, thereby shows the endovascular interventional RF coil potential in accelerated imaging speed and improved detection sensitivity as a result of its proximity to the imaging target. An absolute SNR and the better decoupling performance will be offered, and the numerical simulation, feasibility and performance was validated at 7T…The third section shows the design of a 16-channel RF hand coil system for MR imaging and spectroscopy at 7T. The concurrent acquisition of this 16-channel RF coil can be used to generate high resolution and SNR imaging, which can provide information on anatomic and metabolic imaging in vivo and for therapy monitoring and for diagnosis and auguring of diseases. However, building a hand/wrist coil array with a large number of channel count is technically challenging due to the limited space and asymmetric anatomic geometry. Here we propose a 16-channel RF surface coil array system using unique coil element layout which is capable of providing required imaging coverage for hand/wrist MR imaging at 7T. Parallel magnetic resonance imaging (MRI) necessitates the use of an array of RF coil components with varying susceptibility distributions and low electromagnetic coupling. This project's aim was to provide a new method for induced current compensation or removal for improved coil part decoupling and testing in phantom MR photos Simultaneous imaging of multiple segments of the hand is significant for obtaining clinically meaningful information with superior MRI/MRS in vivo.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gaddipati, Sirihaas
Contributors dc:contributor
  • Zhang, Xiaoliang
  • Biomedical Engineering

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
  • Copyright retained by author.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/87758

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Gaddipati, Sirihaas. Design and Numerical Investigation of RF Transceiver Arrays for 7T MR Imaging in Humans. State University of New York at Buffalo, 2021. http://hdl.handle.net/10477/87758