Back to search

State University of New York at Buffalo

Reduce Penumbra for 3D X-Ray Reconstruction

Abstract

dc:description.abstract

X-ray computed tomography (CT) is an imaging technique in which the three-dimensional (3D) structure of a sample is reconstructed on the basis of two-dimensional projections formed by the penetration of X-rays at different projection angles. It allows us to see what is inside the objects in a non-destructive way. Spot geometry is a significant source of error in computed tomography (CT) images. Due to the fact that X-rays do not originate from a single point source, artifacts are produced. There is a penumbra effect in particular, which results in poorly defined edges within a reconstructed volume. This dissertation focuses on reduce the penumbra blur in the x-ray projections. For resolving the penumbra effect, we propose a deconvolution method. We show that the penumbra blur can be represented as a convolution process, with the x-ray spot geometry as the kernel. To remove artifacts during the deconvolution process, two techniques are included: one for removing projection boundary ring artifacts and another for removing sharp edge ring artifacts. The algorithm can be implemented on the CUDA platform and run in a reasonable amount of time. The results on synthetic data and real images quantitatively and qualitatively demonstrated the performance of our algorithm. This work improves the sharpness of the x-ray reconstruction volume edges.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ni, Xin
Contributors dc:contributor
  • Cheng, Ping-Chin
  • Electrical Engineering

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
  • Copyright retained by author.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/87886

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ni, Xin. Reduce Penumbra for 3D X-Ray Reconstruction. State University of New York at Buffalo, 2021. http://hdl.handle.net/10477/87886