State University of New York at Buffalo
Seismic Retrofit of Reinforced Concrete Shear Walls Using Selective Weakening and Self-Centering
Abstract
dc:description.abstractThe objective of this dissertation is to investigate the feasibility of retrofitting reinforced concrete (RC) buildings with non-ductile slender reinforced concrete shear walls using weakening and self-centering. This retrofit solution aims at minimizing damage and residual drift to ensure resiliency. Past earthquakes have shown that RC buildings with shear walls designed according to older code provisions (e.g. ACI 318-63) may be susceptible to web or boundary element concrete crushing or undesirable shear-induced failure modes. This research introduces a new retrofit solution based on the concepts of selective weakening and self-centering. In this method, shear walls are selectively weakened by creating a discontinuity of concrete and cutting selected reinforcing bars at the wall base. Self-centering is achieved by the addition of a restoring force through external unbonded post-tensioned strands. Experimental, numerical, and analytical investigations were conducted to predict and measure the strength, displacement capacity, and failure modes of pre- and post-retrofit walls, understand the effect of different parameters on the response of pre- and post-retrofit walls, assess the applicability of the retrofit solution to walls with different heights and reinforcement layouts, and evaluate the efficacy of the proposed retrofit solution to alter failure modes. Quasi-static cyclic testing of three one-third length scale specimens, one pre-retrofit and two post-retrofit walls, demonstrated that the proposed retrofit method changed a shear/flexure response to a more ductile rocking response. The damage (concrete cracking and crushing) was significantly less in the post-retrofit specimens. The strength and secant stiffness of the post-retrofit walls were equal to or lower than the pre-retrofit specimen. Energy dissipation and residual drift of post-retrofit specimens were consistently lower than the ones of the pre-retrofit specimen. Detailed 3D and simplified fiber-based finite element models were developed and validated against test data. A parametric study of walls using quasi-static cyclic loading was conducted to investigate the effect of axial load, debonded height, and the amount of energy dissipating bars on the response of post-retrofit walls. The amount and eccentricity of energy dissipating bars were the most influential parameters on residual drift and energy dissipation. The validated models were used to understand the collapse capacity of a 2D frame with pre- and post-retrofit RC walls. The retrofit increased the collapse margin for three- and six-story buildings with different reinforcement layouts, except when all vertical reinforcing bars were cut. Semi-empirical and mechanics-based analytical methods were able to accurately predict the failure mode and the associated force and displacement capacity for pre-retrofit walls. Analytical methods of post-retrofit walls slightly overestimated the strength.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Basereh, Sina; 0000-0003-3798-3090
- Contributors dc:contributor
-
- Okumus, Pinar
- Civil, Structural and Environmental Engineering
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Copyright retained by author.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/87942