Study of B1 Field Distribution for Loop Coil with Different Bending Angles at 3T
Abstract
dc:description.abstractMagnetic Resonance Imaging primarily known as MRI is an imaging modality that use strong magnetic field to generate high resolution images of the organs and soft tissues inside the body. Recently, the interest in mechanically flexible RF coils has grown rapidly in the MR community. The main benefit expected in comparison to rigid coils is a higher achievable signal-to-noise ratio (SNR) in case of strong variations of the targeted anatomy across patients. However the high SNR is due to the proximity of the surface coil to the human body part but this increase in signal is not consistent with the bending of the coil. It is expected that magnetic field distribution will keep on increasing with the increased proximity of the coil with body part, but it may not be the case ideally. The magnetic flux starts to cancel out with the increased proximity between the two ends of coil. The purpose of this work is to model and simulate the mechanically flexible single channel RF coil at different bending angles for 3T MRI. The paper focus on the B1 field distribution inside the phantom at different coil bending angles and determine the best coil bending angle that will generate the highest B1 Magnetic Field inside the phantom and the least magnetic field cancellation at the center of phantom. Paper also focus on the significance of surface coil on the reduction of input excitation power. Simulation is performed in COMSOL Multiphysics Simulation software and results include the magnetic field distribution generated by the coil inside the phantom at different coil bending angles. Results include magnetic and electric field distribution of the coronal, sagittal and transverse planes of the phantom at 9 different bent angles. It also includes the comparative quantitative analysis of magnetic field at different dielectric properties of the phantom. SAR distribution results for all the central phantom planes are calculated too. The dielectric properties selected are in reference to the human body. Based on the shape and flexibility, it can be best used for imaging musculoskeletal targets like wrist, knee, elbow and ankle.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sharma, Tripta
- Contributors dc:contributor
-
- Zhang, Xiaoliang
- Biomedical Engineering
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Copyright retained by author.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/87956