State University of New York at Buffalo
Development of High Impedance Microstrip Resonators and Design of Mitten RF coil Arrays for Ultrahigh Field MR Imaging
Abstract
dc:description.abstractMicrostrip resonator has been used as the radio frequency (RF) transceiver for magnetic resonance signal excitation and reception. Its application in parallel imaging could achieve faster imaging speed and better image quality. Mutual coupling is one of the major challenges in designing multichannel RF transceiver array which is required in parallel imaging technology. The mutual coupling among the array elements causing resonant frequency shift, input impedance changes, and radiation pattern change. The current solutions to address mutual coupling include inductive decoupling, capacitive decoupling, and high impedance coil decoupling methods. In this thesis, we propose a novel design of a microstrip resonator to improve its decoupling performance in multichannel transceiver arrays using the meander strip conductor. Due to the increase in inductance leading to higher impedance, the decoupling performance is enhanced. The new design requires no additional capacitors or inductors, making the RF transceiver array compact and robust. Multiple performance tests are used to verify the result, and by using the proposed meander line microstrip, a nine-channel mitten microstrip array is designed and investigated for human hand MR imaging at the ultrahigh field of 7T (300MHz). Studies on the mitten array demonstrate excellent decoupling performance among resonant elements at 300MHz, thus higher SNR and better parallel imaging performance over the conventional microstrip design are expected. All experiments in this study are implemented using COMSOL Multiphysics Simulation software, and results include the electric and magnetic field calculation and analysis in both conventional microstrip resonator and meander line microstrip resonator. It also includes the comparative quantitative analysis of magnetic fields at different distances between the elements and different excitation locations. The nine-channel mitten microstrip array is tested with a phantom mimicking human muscle.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gao, Tianyu; 0000-0002-3110-2638
- Contributors dc:contributor
-
- Zhang, Xiaoliang
- Biomedical Engineering
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Copyright retained by author.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/88003