State University of New York at Buffalo
Acceleration of Quantitative Magnetic Resonance Imaging Using Compressed Sensing Method
Abstract
dc:description.abstractQuantitative magnetic resonance imaging (MRI), such as diffusion imaging and parameter mapping, is widely used in neuroscience research and clinical diagnosis. However, the application is limited by lengthy acquisition time. Compared to conventional MRI that only generates a single contrast image, quantitative MRI usually requires multiple images with different contrasts, which significantly prolongs scan time. This is more challenging in three-dimensional (3D) applications where multiple slices are acquired, it usually takes from several minutes to several hours in acquisition, which makes it impractical in clinical uses. To adjust this issue, many techniques were used to accelerate quantitative imaging such as partial Fourier, parallel imaging. In recent years, compressed sensing (constrained reconstruction from reduced k-space acquisition) has been investigated for shortening scan time. In this thesis, we developed the following methods to accelerate both diffusion-MRI and parameter mapping: (i) kernel-based low rank (KLR) and (ii) self-trained kernel principle component analysis (PCA) model. The kernel-based low rank (KLR) method is developed to learn the highly non-linear correlations among different images from low-resolution images, which is reconstructed from the fully sampled center region of the k-space and used as the training data. The correlations can then be used to reconstruct high-resolution images from extended, under-sampled k-space. In this way, the KLR method can self-adapt to different quantitative acquisition schemes and tissue microstructures. The KLR method is further extended to a self-trained kernel principle component analysis (PCA) model, where the non-linear correlations are learned from another parametric model in parameter mapping. This method can benefit from the fact that: (1) the parametric model can generate an infinite number of training data given different reasonable parameters. (2) the training process can be performed offline, which will reduce the computational complexity. Considering the other factors such as noises that may affect the non-linear correlations among different images, we also added total variation in the spatial domain to smooth the images. The kernel-based low-rank method was validated on both diffusion-MRI and parameter mapping. Specifically, in diffusion-MRI, a full k-space 3D data of post-mortem mouse brains were retrospectively reconstructed and compared with the conventional compressed sensing (CS) method in terms of image quality and ability to resolve complex fiber orientations and connectivity. For T1ρ imaging, a prospectively under-sampled 3D cartilage data was reconstructed and quantitatively compared to the fully sampled gold standard. The reconstructed results demonstrated acceleration factors up to 8 and were likely to enhance ability in both probing tissue microstructure and clinical use. The self-trained kernel PCA method was validated on both T2 phantom and in-vivo T2 mapping data where the T2 parametric model is applied, compared to the linear PCA method, our method can achieve fewer errors and the reduction factors up to 5.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zhang, Chaoyi
- Contributors dc:contributor
-
- Ying, Leslie
- Electrical Engineering
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/88113