Back to search

State University of New York at Buffalo

Image-Based Radiopharmaceutical Imaging Tracer Dosimetry by Using Monte Carlo Simulation

Abstract

dc:description.abstract

The purpose of this thesis is to obtain dosimetry for a new PET imaging radiopharmaceutical agent through the GATE (GEANT4 Application for Tomographic Emission) Monte Carlo simulation package. Materials and Methods: We performed three dosimetry studies: 1) a simple point-source phantom 2) a MOBY (4D Mouse Whole Body) digital phantom; and 3) a mouse injected with a monoclonal antibody-based PET imaging agent (124I-hJAA-F11), with PET images acquired on a microPET Focus120 animal scanner, for practicing the syntax of GATE and validating the simulated result against analytical estimation. Results: The studies of the simple point-source and MOBY phantoms showed the difference between GATE scores and analytical calculations was 0.01 % to 0.5 %, respectively. Also, S values were obtained for the MOBY phantom from the liver to target organs and compared with those of (Xie & Zaidi, 2013). For the PET imaging agent, the total body absorbed dose normalized to administered activity was found to be 306.1 mGy/MBq on the 25-gram mouse body from 72 μCi activity of the I-124 radiotracer source. Additionally, the self-absorbed dose S-value was 0.0011 mGy/MBq*sec for mouse body to mouse body. To validate this study, the S-value, which was obtained on the MOBY phantom, was compared to those found in (Xie & Zaidi, 2013), which is 0.0014 mGy/MBq*sec. Conclusions: This thesis obtained dosimetry for several models and real mouse images. The results revealed that a Monte Carlo simulation can improve radiation dosimetry accuracy. This is because Monte Carlo simulation generates more accurate results for activity distribution and tissue composition than traditional methods.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gultekin, Kadir; 0000-0002-9736-6302
Contributors dc:contributor
  • Yao, Rutao
  • Radiology

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/88124

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Gultekin, Kadir; 0000-0002-9736-6302. Image-Based Radiopharmaceutical Imaging Tracer Dosimetry by Using Monte Carlo Simulation. State University of New York at Buffalo, 2022. http://hdl.handle.net/10477/88124