Back to search

State University of New York at Buffalo

Enhancement of the Scattered Radiation Display System Dose Management Module for Occupational Eye-Lens Dose in Fluoroscopic Interventional Procedures

Abstract

dc:description.abstract

Over the past 3 decades, the increasing use of fluoroscopically-guided interventional (FGI ) procedures has caused a substantial increase in occupational x-ray exposure that makes staff members susceptible to radiation-induced health hazards including eye-lens cataract formation. Our group has previously developed the Dose Tracking System (DTS) to monitor the patient’s skin dose during long FGI procedures; however, the radiation dose is a concern not only for the patient but also for the personnel in the procedure room. The Scattered Radiation Display System Dose Management Module (SDS DM ) is a staff radiation safety awareness module developed by our group which displays a color-coded room scatter distribution in real-time and performs calculations to obtain dose rate throughout the room at waist level. The SDS obtains exposure parameters using the imaging system’s CAN-bus that can be used in real-time for immediate feedback or can be stored in a log file that can be replayed later. The SDS display uses a look-up table (LUT) library of scatter distributions created by Monte-Carlo (MC) simulations for various system exposure parameters. The work in the thesis focuses on the expansion of the SDS LUT library to include scatter distribution maps at eye level for increased awareness of the potential for radiation cataractogenesis. We generated a library of room scatter radiation dose distributions at eye level using Monte Carlo code and incorporated the functionality in the SDS that permits the user to change distribution maps between eye level and waist level during playback. An SDS dose rate report can now be created that documents dose rate at both eye and waist level at the interventionalist’s location during an exposure event and that includes the color-coded scatter distribution to help staff members understand the radiation risks. This enhanced system was used to analyze the dose rate at the eye level for several clinical cardiac interventional procedures by retrospective analysis using log files acquired with IRB approval. The dose rates obtained at different gantry angulations were compared between procedures.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dhonde, Rushikesh
Contributors dc:contributor
  • Bednarek, Daniel
  • Biomedical Engineering

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/88187

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Dhonde, Rushikesh. Enhancement of the Scattered Radiation Display System Dose Management Module for Occupational Eye-Lens Dose in Fluoroscopic Interventional Procedures. State University of New York at Buffalo, 2022. http://hdl.handle.net/10477/88187