State University of New York at Buffalo
Enhancement of the Scattered Radiation Display System Dose Management Module for Occupational Eye-Lens Dose in Fluoroscopic Interventional Procedures
Abstract
dc:description.abstractOver the past 3 decades, the increasing use of fluoroscopically-guided interventional (FGI ) procedures has caused a substantial increase in occupational x-ray exposure that makes staff members susceptible to radiation-induced health hazards including eye-lens cataract formation. Our group has previously developed the Dose Tracking System (DTS) to monitor the patient’s skin dose during long FGI procedures; however, the radiation dose is a concern not only for the patient but also for the personnel in the procedure room. The Scattered Radiation Display System Dose Management Module (SDS DM ) is a staff radiation safety awareness module developed by our group which displays a color-coded room scatter distribution in real-time and performs calculations to obtain dose rate throughout the room at waist level. The SDS obtains exposure parameters using the imaging system’s CAN-bus that can be used in real-time for immediate feedback or can be stored in a log file that can be replayed later. The SDS display uses a look-up table (LUT) library of scatter distributions created by Monte-Carlo (MC) simulations for various system exposure parameters. The work in the thesis focuses on the expansion of the SDS LUT library to include scatter distribution maps at eye level for increased awareness of the potential for radiation cataractogenesis. We generated a library of room scatter radiation dose distributions at eye level using Monte Carlo code and incorporated the functionality in the SDS that permits the user to change distribution maps between eye level and waist level during playback. An SDS dose rate report can now be created that documents dose rate at both eye and waist level at the interventionalist’s location during an exposure event and that includes the color-coded scatter distribution to help staff members understand the radiation risks. This enhanced system was used to analyze the dose rate at the eye level for several clinical cardiac interventional procedures by retrospective analysis using log files acquired with IRB approval. The dose rates obtained at different gantry angulations were compared between procedures.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dhonde, Rushikesh
- Contributors dc:contributor
-
- Bednarek, Daniel
- Biomedical Engineering
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng