State University of New York at Buffalo
A Data Driven Pipeline to Quantify Blood Flow in the Circle of Willis for Patients with Intracranial Atherosclerotic Disease (ICAD)
Abstract
dc:description.abstractIntracranial atherosclerotic disease (ICAD) causes progressive stenosis in intracranial arteries subsequently leading to cerebral hypoperfusion, myocardial infarction, thromboembolism, etc. finally resulting into a stroke. It is one of the major contributors to ischemic and recurrent strokes worldwide. Many imaging biomarkers based on the degree of stenosis, vessel wall enhancement, plague pathophysiology etc. are used to identify and diagnose ICAD based stenotic lesions. Several diagnostic measures including medical management, based on antithrombotic drugs are prescribed along with endovascular intervention treatments such as stenting, balloon angioplasty, etc. Despite this, ICAD still posits a major threat for stroke recurrence and transient ischemic attack (TIA) thus calling for a distinct need to objectively quantify hemodynamic risk metrics. Some of the computational modeling studies have correlated relative wall shear stress near the stenotic region with the progression of atherosclerosis in longitudinal studies. Others have tried to correlate pressure wire-based measurements across the stenosis with computational fluid dynamics (CFD) simulations under similar conditions. But in doing so, they neglected the use of patient specific boundary conditions, considered a smaller patient cohort, used incomplete geometries, and made a number of other modeling assumptions. Hence there is a need to design an integrated automated/semi-automated 0D/1D pipeline that can adapt to patient specific topological features such as occlusions, stenosis, aneurysms, etc. and morphological attributes such as radius, curvature, bifurcation angles etc. with the modularity of accommodating physiological constraints in the form of 0D lumped parameter formulations or 1D laws addressing the inherent nonlinearities in the vasculature. Although there have been many personalized cerebrovascular frameworks that have used open loop configurations based on 3D/1D models representing the geometry, coupled with 0D boundary conditions at the outlet, not many of them provide a user defined way to incorporate patient specific geometries, define mathematical models, update boundary conditions and solve for the output hemodynamics, keeping in mind the underlying disease to be addressed. My thesis focuses on developing for the first time an image-based pipeline that can identify global hemodynamics for patients with ICAD and highlight the effectiveness of using cerebral autoregulation with patient specific data…
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dholakia, Saumya
- Contributors dc:contributor
-
- Tutino, Vincent
- Mechanical and Aerospace Engineering
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/88192