Electrochemical Mitigation of Biofouling on Metallic Implants

Abstract

dc:description.abstract

Metal implant biofouling caused by protein adsorption and bacterial biofilm formation remain one of the major issues faced by metal based devices in vivo. Implanted devices elicit foreign body reaction by protein adsorption and are at risk for implant-associated infection (IAI), which can be detrimental to the implant. Since most implanted devices have metallic parts, the work presented here sought to utilize electrical stimulation for removal and eradication of biofouling on different metallic surfaces and to investigate the electrochemical changes associated with electrical stimulation, to better understand the impact of electrical stimulation on these non-specific interactions. Fibrinogen interaction with cathodically polarized gold surface was characterized by electrochemical methods in order to determine the effectiveness of cathodic voltage-controlled electrical stimulation (CVCES) in mitigating protein based biofouling. The impact of fibrinogen adsorption on the electrochemical potential and electrochemical impedance characteristics of gold were evaluated. It was determined that fibrinogen adsorption affected the gold electrode/electrolyte interfacial properties. Electrochemical quartz crystal microbalance (eQCM) studies for real-time analysis of CVCES effect on fibrinogen adsorbed on gold were conducted. These studies showed that fibrinogen desorption from gold surfaces occurred in a voltage dependent manner. Scanning Electrochemical Microscopy (SECM) studies were conducted to investigate the mechanisms behind fibrinogen removal. Microenvironment surrounding gold during an electrical stimulation measured for hydrogen evolution and pH change It was determined that the water reduction reaction, which generates hydrogen, was involved in desorption reactions of fibrinogen. Also, pH reached a high alkaline value of ~ 12 during application of stimulation, which was another contributing factor towards fibrinogen removal. This suggested, the desorbing effects of fibrinogen are associated with the changes in electrochemical environment caused by CVCES…Overall, this work utilized CVCES and showed that it is an effective strategy in mitigating protein-based and bacteria-biofilm fouling on metallic implants. The electrochemical changes caused by CVCES resulting in anti-fouling properties were also investigated.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mohanraj, Gowtham
Contributors dc:contributor
  • Ehrensberger, Mark
  • Biomedical Engineering

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/88330

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mohanraj, Gowtham. Electrochemical Mitigation of Biofouling on Metallic Implants. State University of New York at Buffalo, 2022. http://hdl.handle.net/10477/88330