State University of New York at Buffalo
Design and Development of an Electrospray Ionization Zoom Time-of-Flight Mass Spectrometer
Abstract
dc:description.abstractIn this dissertation, an electrospray ionization zoom time-of-flight mass spectrometer (ESI-Zoom-TOFMS) is described for the first time. Zoom-TOFMS combines conventional TOFMS operation with constant momentum acceleration TOFMS (CMA-TOFMS) into a single instrument with the two modes of operation selected as desired. The CEA-TOFMS mode offers full mass spectral coverage with modest mass resolving power, while the CMA-TOFMS mode offers enhanced mass resolving power over a narrow mass range. Constant momentum acceleration is confirmed experimentally using retarding potential analysis (RPA). RPA is also used to estimate the initial energy distribution along the drift axis. Additionally, energy filtering is demonstrated which allows for the repetition rate of the instrument to be increased thereby increasing the duty cycle. The improvement in duty cycle translates to a higher ion utilization efficiency which leads to higher sensitivity and lower limits of detection. A dual-stage mirror for use with ESI-Zoom-TOFMS is also described and a preliminary investigation was carried out using Monte Carlo calculations. Mass resolving power was shown to improve for a target m/z as compared to conventional TOFMS and ESI-Zoom-TOFMS operation with a single stage ion mirror. Much like that observed in ESI-Zoom-TOFMS with a single-stage ion mirror, a small range of ions surrounding the target m/z benefits from detection at times close to the energy focus time. Further, the initial energy and spatial distributions are shown to affect the anticipated mass resolving power with the initial spatial distribution remaining the principal limiting factor governing the achievable mass resolving power...Finally, constant momentum acceleration has been applied to resonance ionization mass spectrometry in an attempt to improve the fidelity of certain measurements. A new approach to RIMS using CMA is described for the first time, with special emphasis on the measurement of atomic ions of the same nominal m/z that are to be detected in a single RIMS experiment. This novel RIMS (CMA-RIMS) strategy provides an improved method to resolve isotopes which experience isobaric overlap. The use of CMA-RIMS in place of a conventional RIMS approach is exploited to impart different ion energies to the ions produced by resonance ionization in RIMS. In this way, isobaric overlaps that are difficult to resolve by traditional RIMS are capable of being resolved by the use of constant momentum acceleration.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Brais, Christopher
- Contributors dc:contributor
-
- Ray, Steven
- Chemistry
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/88359