Back to search

State University of New York at Buffalo

A Method to Determine Patient Eye-Lens Dose During Fluoroscopically-Guided Neuro-Interventional Procedures

Abstract

dc:description.abstract

Fluoroscopically-guided neuro-interventional procedures can result in high patient radiation dose and associated deterministic risks. Skin dose has been a primary concern for these procedures due to the risk of skin effects starting with erythema, which has a dose threshold of 2000 mGy. Our group has developed the Dose Tracking System (DTS) to track patient radiation skin dose during interventional fluoroscopic procedures and allow for real-time dose management. However, these procedures also have the potential to deliver high dose to the patient eye-lens, with one study showing that sixteen percent of embolization procedures resulted in doses exceeding 500 mGy, which is the estimated dose threshold for radiation-induced cataracts determined by the ICRP. The lens of the eye is thus a very radiosensitive organ whose dose must be minimized, while still being able to achieve the clinical task. To allow the interventionalist to balance the risks versus benefit of proceeding with a procedure, real-time feedback of patient dose is needed. This work focuses on developing a system that can be incorporated into the DTS to give real-time feedback to the physician of the patient’s eye-lens dose. To begin, a patient eye-lens dose database was generated using Monte-Carlo (MC) simulations. These were done using National Cancer Institute of CT (NCICT) computational phantoms to create a dataset of lens dose values for the right and left eyes to train the deep learning (DL) models. The dataset was obtained for a range of geometric and exposure parameters used in neuro-interventional procedures including entrance-field size, kVp, beam filter, gantry angulation, cephalometric dimensions, and patient head position relative to the beam isocenter. These simulations show how heavily the patient eye-lens dose depends on the variation of these parameters, with some percent differences in eye-lens dose reaching 2000% for a single exposure/projection depending on if a certain parameter is changed. The incorporation of all of these different parameters helps to create a patient eye-lens dose database that is a more accurate representation of the clinical scenario and will allow for training of the system to predict patient eye-lens dose...

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Collins, Jacob
Contributors dc:contributor
  • Bednarek, Daniel
  • Radiology

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
https://hdl.handle.net/10477/88390

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Collins, Jacob. A Method to Determine Patient Eye-Lens Dose During Fluoroscopically-Guided Neuro-Interventional Procedures. State University of New York at Buffalo, 2022. https://hdl.handle.net/10477/88390