Back to search

State University of New York at Buffalo

Retention Force Provided by Custom-Made and Native Locator Abutments - An In Vitro Study

Abstract

dc:description.abstract

Purpose of the study: This in vitro study evaluated the retention force of custom-made locator implant abutments placed at 0, 15, and 30 degrees of angulation. Material and Methods: Forty implant specimens were produced, and were divided into four groups: The native locator abutment used as control, while the experimental groups consisted of customized locator abutments fabricated at 0, 15 and 30 implant angulation. Using a resin jig for each angulation, forty implant analogs were placed in the first molar area of a typodont. The analog was scanned, and custom locator and denture analogs were designed and milled for each group using CAD/CAM software (3Shape) and 5-axis milling machine (PM7, Ivoclar Vivadent). The specimens were subjected to chewing simulation corresponding to six months of clinical service. Tensile retentive force was recorded using a universal testing machine before and after chewing simulation. Pre-test and post-test pictures were taken for all specimens using a digital stereo microscope (Dinolite) to visually assess the attachment components’ wear. Results: All groups showed significant increase in retentive force values after chewing fatigue loading (p>0.05). However, no significant difference was found between native and custom locators at 0, 15 , and 30 before and after fatigue testing (p=.368). One 30 specimen showed slight wear of the metal abutment, while four nylon inserts in the 15 and 30 groups had slight signs of wear. Conclusions: Custom locator abutments at 0, 15 and 30 show similar retentive force to native locator abutments before and after fatigue testing. Customized angled abutments may lead to nylon insert damage, requiring frequent replacement.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mandourah, Heba
Contributors dc:contributor
  • Sadid-Zadeh, Ramtin
  • Oral Sciences

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
https://hdl.handle.net/10477/88391

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Mandourah, Heba. Retention Force Provided by Custom-Made and Native Locator Abutments - An In Vitro Study. State University of New York at Buffalo, 2022. https://hdl.handle.net/10477/88391