Back to search

State University of New York at Buffalo

The Scattered Radiation Display System: A New Paradigm for Staff Member Dose Management and Training for Fluoroscopically-Guided Interventional Procedures Using Virtual Reality, Monte Carlo Simulations, and Artificial Intelligence

Abstract

dc:description.abstract

Fluoroscopically-guided interventional (FGI) procedures used for treating vascular pathologies, such as aneurysms and stenoses, can be long in duration leading to an increased risk of deterministic and stochastic effects. To mitigate the onset of deterministic skin effects post-procedure, our group developed the real-time patient skin Dose Tracking System (DTS), which is now a product licensed to Canon available for distribution with a variety of biplane and single-plane angiography systems. In addition to an increased risk to the patient, prolonged procedures increase risk to staff members. While interventionalists are typically stationary, and remain behind tableside shielding, during the course of FGIs, ancillary staff members, such as the technologist, nurse, and anesthesiologist, may move around and neglect additional shielding available in the room. The as low as reasonably achievable (ALARA) principle maintains that absorbed radiation dose for both the patient and staff members should be minimized while concurrently ensuring proper treatment outcome. Standard methods exist for monitoring staff dose levels either during or after procedures in the form of real-time ionization chamber dosimeters or thermoluminescent dosimeters (TLDs). However, these dosimeters are typically worn at the collar level and waist level, only providing point-dose estimations. With the complex dynamics of scatter distributions in the interventional room, in addition to the inability to view x-ray radiation with the naked eye, the staff remain unaware of how to optimize their location along with geometric and exposure parameters. The primary work presented in this dissertation is a comprehensive software system capable of monitoring changes to scatter distributions during FGIs, as well as extra-procedure training, called the scattered radiation display system (SDS). The SDS dose management module (DM) functions in real-time via interfacing to an angiography system with a controller area network (CAN) bus. Hexadecimal data packets containing geometric and exposure information are fed off of the CAN to the SDS directly and utilized to properly select a color-coded scatter distribution for display. The displayed distribution is derived from pre-calculated matrices using EGSnrc Monte Carlo (MC). Two methods are compared and contrasted in this dissertation for providing a sufficient amount of information to determine the displayed distribution: 1) a discrete look-up-table consisting of 3D MC pre-calculated distributions which correspond to configurations of exposure and geometric parameters known to alter the spatial shape of the distribution; 2) a regressional deep neural network (DNN) which predicts the displayed distribution using a dataset of MC pre-calculated distributions…

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Troville, Jonathan; 0000-0002-5090-5698
Contributors dc:contributor
  • Bednarek, Daniel
  • Radiology

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/88394

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Troville, Jonathan; 0000-0002-5090-5698. The Scattered Radiation Display System: A New Paradigm for Staff Member Dose Management and Training for Fluoroscopically-Guided Interventional Procedures Using Virtual Reality, Monte Carlo Simulations, and Artificial Intelligence. State University of New York at Buffalo, 2022. http://hdl.handle.net/10477/88394