State University of New York at Buffalo
Analyzing and Improving Thermal Comfort and Air Quality of Indoor Spaces Using CFD
Abstract
dc:description.abstractA numerical study was pursued to improve occupant thermal comfort, air quality and energy efficiency of heating, ventilation and air-conditioning (HVAC) systems in buildings. Computational fluid dynamics (CFD) was used to numerically investigate the air flow dynamics and particle transport in different indoor scenarios. Small scale motions were predicted using the Reynolds Averaged Navier-Stokes (RANS) equations. A coupled Eulerian-Lagrangian approach was employed to model the interaction between pathogens and air. A case study based approach was used model and examine the behavior of a real-world thermal zone to evaluate occupant thermal comfort and energy consumption of the HVAC system. The potential of implementing an adaptive diffuser to the HVAC system was explored by adjusting the diffuser operation (1) controlling the binary operation of air flow (turning flow on and off) by distributed thermal feedback from room, and (2) adjusting the flow direction to target the occupant need in an environment. The coupling of distributed feedback and independent directional flow improved thermal comfort while reducing energy demands by approximately 25%. The second part of the study was focused on improving indoor air quality by analyzing the dispersion of airborne infectious diseases like the novel Coronavirus. Two ways of minimizing the risk of infection were investigated. The first way was by reducing indoor pathogen concentration by optimizing HVAC operation by examining 5 different HVAC scenarios and the second way was to limit the concentration of expelled pathogens at the source by using personal-protection equipment. The efficacy of an air sterilization system that integrated with a building air handling unit was examined. Results showed that contaminants, especially aerosols, remained airborne for prolonged periods. Using an air sterilization unit reduced the pathogen concentration in a clinical setting by 25% and nullified the possibility of spreading the infection to other sub-spaces of the building through air re-circulated by the HVAC system. To address the rising concerns for safety of musicians during the pandemic, the air flow patterns and airborne pathogen transport induced by brass instruments in a music hall were examined. The results showed that using a mask-like covering at the opening of instruments (bell) reduced the concentration of escaping pathogens and reduced the distance that particles could travel. Overall, the findings of this study showed that using bell covers with rightly positioned Plexiglas partitions limited the transmission of pathogens from one musician to another. Lastly, efficacy of different face masks and face shields was investigated and it was found that the ASTM level 3 mask was most effective in limiting the spread of infection and results implied that a social distance of 3 feet was sufficient when wearing a face protection equipment. The results showed that size and fit of a face shield were important and a long face shield with thick foam and vertically oriented with the face was most effective in capturing aerosols and was recommended for people with disabilities or children.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Joshi, Vedant; 0000-0002-0995-6936
- Contributors dc:contributor
-
- Battaglia, Francine
- Mechanical and Aerospace Engineering
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- https://hdl.handle.net/10477/88687