State University of New York at Buffalo
Using Varian TrueBeam Developer Mode and Varian TrueBeam couch (6-DOF) to Simulate 4D Respiratory Motion and to Counteract the Phantom Motion in Real Time
Abstract
dc:description.abstractBackground: Quality assurance of motion management strategies in the context of external beam radiotherapy requires the use of a phantom with motion capabilities. Usually, the Motion phantoms are expensive, may have limited dimensions or configuration and may limit motion only along one axis. They may also be lacking important features like simulating motion by incorporating actual patient respiratory trace or may not have provisions to accommodate different types of chambers/films etc. for quality assurance purposes. They usually require specialized care and very gentle handling. However, TrueBeam medical linear accelerator allow low-level control of various machine and beam parameters under computer control and allow creation of standard motion designs by simulating equivalent couch motion for research purposes. It can incorporate patient respiratory trace by simulating equivalent motion phantom movement and theoretically can convert any phantom to a motion phantom by intelligently moving the couch based on the preplanned trajectory from an appropriate computer file. Purpose: To evaluate the spatial, temporal and dosimetric fidelity of the Varian TrueBeam couch in mimicking a motion representative of a phantom with motion capabilities using Developers Mode. To determine the possibility of converting user-defined sinusoidal patterns into TrueBeam couch movement and to determine the possibility of converting RPM captured trace of motion phantoms into TrueBeam couch movement. In addition, to determine the possibility of using the TrueBeam couch to counteract the movement of motion phantom in real time, a novel form of respiratory motion management. Methods: Standalone software was developed for writing an XML code either for user-defined sinusoidal couch motions with various amplitudes and periods or converting an existing respiratory trace to equivalent motion of TrueBeam Linac couch…Conclusion: TrueBeam couch can effectively simulate user defined sinusoidal patterns and mimic phantom motion by moving the couch in 3D allowing the possibility of converting any stationary phantom into equivalent motion phantom. It is also possible to make the couch move in opposite direction to counteract the motion of the phantom in real time which can help in reducing PTV margins and hence normal tissue irradiation.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Cao, Yanan
- Contributors dc:contributor
-
- Malhotra, Harish
- Radiology
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/88692