Back to search

State University of New York at Buffalo

Efficacy and Comfort Level with Non-Sliding Lingual Orthodontic Technique (BRIUS™) Versus Labial Fixed Appliances: A Randomized Controlled Clinical Pilot Trial

Abstract

dc:description.abstract

Introduction: BRIUSTM (BR) is a company that introduced a novel fixed lingual appliance in 2017. The appliance consists of Independent Movers ® (IM) that can move teeth individually with minimal side effects. According to the manufacturer, BR reduces treatment duration since a single IM can complete most, if not all, treatment phases. BR is also claimed to reduce treatment discomfort because no adjustments are necessary between visits. Objectives: This study had three aims: 1) to identify whether BR is able to move teeth a larger distance during the leveling and aligning stage in the x, y and z planes than labial full fixed appliances (LFFA); 2) to compare changes in Little’s Irregularity Index (LII) in the leveling and aligning stage between BR and LFFA; and 3) To asses comfort levels perceived by patients undergoing treatment with BR versus LFFA. Methods: This is a randomized controlled clinical pilot trial on 13 subjects, 7 in the BR group and 6 in the LFFA group. The patients were evaluated at four time points: before initial bonding (T1), 6 weeks (T2), 12 weeks (T3) and at 18 weeks (T4) into treatment. Intra-oral scans were obtained at all time points and superimpositions were completed to identify the total distance travelled by each tooth in the x, y and z planes. LII was measured at T1 and T4 timepoints. To assess comfort levels, patients were requested to complete an online diary comfort questionnaire for 7 days after T1, T2, T3 and T4. Results: There was no difference in LII between T1 and T4 when comparing BR to LFFA. All teeth showed no difference in distance travelled between T1 and T4 except LL5 in the x-axis. This tooth moved more in the BR group (P=0.016) than the LFFA group. Discomfort during the first week after bonding was in the with BR and in the lips and cheeks with LFFA group. Tongue discomfort caused by BR lasted for around 3 days. Discomfort after adjustment visits was significantly less in the BR group as compared to the LFFA group in week 3. Conclusion: BR and LFFA were equally effective at leveling and aligning teeth. LFFA caused cheek and lip-borne discomfort while BR caused tongue-borne discomfort during the first week after bonding. Larger studies with longer follow-up durations are needed to obtain more generalizable results.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Al-Zainal, Mohammed
Contributors dc:contributor
  • Al-Jewair, Thikriat
  • Orthodontics

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/88741

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Al-Zainal, Mohammed. Efficacy and Comfort Level with Non-Sliding Lingual Orthodontic Technique (BRIUS™) Versus Labial Fixed Appliances: A Randomized Controlled Clinical Pilot Trial. State University of New York at Buffalo, 2022. http://hdl.handle.net/10477/88741