State University of New York at Buffalo
Characterizing Structural Behavior of Reinforced Concrete Tessellated Structural-Architectural Shear Walls with Interlocking Tiles
Abstract
dc:description.abstractThis dissertation evaluates the performance of a new modular shear wall system designed for replaceability and resilience after extreme loading as well as architectural appeal. The walls are called tessellated structural-architectural (TeSA) walls, and consist of interlocking tiles (modules) with repetitive shapes (tessellations). Tiles of TeSA systems can be interlocking in one direction (1-D interlocking) or two directions (2-D interlocking) and can incorporate self-centering post-tensioning. This dissertation has three main objectives (1) identify modeling approaches and capacity prediction methods suitable for TeSA walls under lateral loading, (2) develop an understanding of the behavior of TeSA walls with varying degrees of tile interlocking and design parameters, and (3) establish a framework to generate fragility functions for TeSA walls. For objective 1, continuum and fiber-based finite element models were developed for TeSA walls. The continuum finite element models were developed for 1-D and 2-D interlocking TeSA walls with and without self-centering post-tensioning, respectively. The continuum modeling approach was validated using test results from a parallel experimental study on 1-D interlocking TeSA wall. The fiber-based finite element models were developed for 1-D interlocking TeSA walls. The fiber-based model was validated using test data and verified by comparing the results with those obtained from the continuum finite element models. The fiber-based models enabled computationally demanding sensitivity, fragility, and system-level analyses. A flexure based sectional analysis method was proposed to evaluate the capacity of TeSA walls with 2-D interlocking tiles. The proposed method predicted the capacity well when compared to capacity obtained from the continuum models. Using a reduced cross-sectional area approach, the level of engagement of the discontinuous concrete sections in resisting lateral loads was demonstrated to be a function of the axial load on the walls. For objective 2, using the models, the performance of the 2-D interlocking wall was compared with that of an equivalent conventional reinforced concrete shear wall. The lateral strength and stiffness of the 2-D interlocking TeSA walls were found to be approximately half of the ones of the benchmark conventional wall. Tile patterns and the level of interlocking influenced the structural response of the TeSA wall and are parameters that can be tuned considering the design objectives. The tile reinforcement ratio and the applied axial load on the wall are two other design parameters that have significant influence on the structural response. For objective 3, a framework for developing fragility functions for 1-D interlocking walls was formulated to evaluate the performance of various tile patterns. Fragility functions were developed using the fiber-based models; considering uncertainties in applied axial loading, tile-interface properties, concrete compressive strength, modeling approach; and using the lateral drift as the demand parameter...
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Syed, Mohammad
- Contributors dc:contributor
-
- Okumus, Pinar
- Civil, Structural and Environmental Engineering
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/88746