Back to search

State University of New York at Buffalo

Development and Validation of Imaging Biomarkers for Risk Assessment of Intracranial Aneurysms

Abstract

dc:description.abstract

Intracranial aneurysms (IAs) are weak bulging spots in the cerebral vasculature that can grow and rupture causing permanent disability or death. However, the rate of rupture of these IAs is low. Current treatment decision of these IAs is made primarily based on the size of the IA at the time of imaging where treatment is favored in larger IAs. However, >40% of all IAs that do rupture are small IAs (<5mm in size). Hence, a better indicator of IA risk is necessary. Vessel wall enhancement (VWE) has emerged as a potential imaging biomarker that can help delineate unstable and rupture prone IAs. Herein, gadolinium-based contrast is introduced into the cerebral vasculature and the amount and pattern of contrast absorbed by different parts of the aneurysm wall is evaluated to determine the risk of IA rupture. However, this is currently assessed manually, and objective metrics are needed to better visualize and understand this phenomenon. To this end, the current work aims to develop objective tools to quantify the pattern and intensity of contrast uptake by different parts of the IA wall. We develop a pipeline to map the amount of contrast absorbed into 3D space and demonstrate the utility of this pipeline in objectively quantifying the amount and pattern of VWE intensity in a cohort of IAs. We found that this pipeline can be used for more objective and accurate characterization of VWE. We then use this tool to evaluate potential correlation between intra-aneurysm hemodynamics and VWE. We found that although there was a weak correlation between the sac averaged hemodynamic values as well as the VWE intensity. However, this effect was not observed at a significant level on a local level. Finally, we used data analysis to extract high-dimensional textural information from the distribution of intensities in the IA wall through radiomics. We use radiomics as a tool to identify high-risk and low-risk IAs based on clinical scores across datasets from different centers. We observed that although the performance of radiomics based models is high when tested on data obtained from the same center using the same scanner, the same model cannot be directly implemented onto imaging obtained from either a different center or using a different scanner. However, radiomics is an objective tool that can be used for more accurate and robust quantification of VWE as compared to other conventionally proposed metrics. We also implemented this pipeline to identify symptomatic and asymptomatic IAs. We again observed that the performance on external datasets is at-par with conventionally proposed metrics. Additionally, we also developed a clinical nomogram that can readily be used as a bed-side tool for risk assessment of newly discovered IAs.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Veeturi, Sricharan; 0000-0002-8114-3817
Contributors dc:contributor
  • Tutino, Vincent
  • Mechanical and Aerospace Engineering

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/88862

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Veeturi, Sricharan; 0000-0002-8114-3817. Development and Validation of Imaging Biomarkers for Risk Assessment of Intracranial Aneurysms. State University of New York at Buffalo, 2023. http://hdl.handle.net/10477/88862