State University of New York at Buffalo
Assessing the Effects of Lateral Orthodontic Forces on Dental Implant Stability: A Pilot Study
Abstract
dc:description.abstractDental implants serve as a gold standard treatment to restore a single edentulous space and partially or completely edentulous jaws due to their long-term success rate, positive impact on a patient’s quality of life, and simplified modern surgical procedure which allows for low morbidity. With our aging population, not only has there been an increasing demand and need for dental implants, but there has also been an increasing desire to seek orthodontic care. Orthodontic treatment amongst elderly populations has become largely sought out due to the value placed on improved function, oral maintenance, and esthetics of natural teeth. As a result, adult patients often require a multidisciplinary approach to their orthodontic treatment; with age comes a greater challenge for providers to consider all factors affecting orthodontically treated teeth, including the impact it has on its underlying bone. There appears to be a lack of research, especially in the adult population, regarding the effects, if any, a lateral loading force could pose on the integrity of endosseous placed implants. The purpose of this study was to evaluate the immediate primary stability of an implant after loading it with a lateral force in order to better understand the maximum force which can be applied to allow for minimal deformation effects. This is a critical step to help dentists determine the best possible timeline and treatment plan to allow for successful primary stability during orthodontic care. A better understanding of the maximum force which can be applied to an implant to allow for minimal deformation affects would be helpful in a clinical setting, mainly one that utilizes the implant as an anchorage unit during orthodontic tooth movement. To construct the study model for this pilot in-vitro study, osteotomies were first carried out on sectioned porcine ribs using a drilling speed of 800 rpm. A sample of three 4.2 S 11mm bone level Astra Tech implants were placed into the ribs and resonance frequency analysis (RFA) was used to measure the Implant Stability Quotient (ISQ) for each sample immediately following implant placement. ISQ is a surrogate measurement of implant stability. This served as the control values for the study. To assess the maximum amount of lateral force which can be applied to achieve immediate primary stability, 5 trials were run for each of the three samples at four varying weights. Since the study aimed to focus on immediate stability, time was held constant for all trials and measured 5 minutes post loading. The subsequent experiments applied weights of 50 grams, 99.2 grams, 149.6 grams, and 200 grams. Digital RFA values were recorded using the Osstell® system during each experiment. The experiment included a weight of 150 (149.6) grams to better simulate clinical practice, as this is most often cited to be a force relevant to common orthodontic practice.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sharma, Ashima
- Contributors dc:contributor
-
- Andreana, Sebastiano
- Oral Biology
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/89160